SMC Corporation of America
Elite Part Number Search
Search Results "HRSH150-AN-40-K"

Description Size 1 Valve Rc1/2 2 Valve Rc3/4 3 Y-strainer (#40) (Accessory) Rc3/4 4 Flow meter Prepare a ow meter with an appropriate ow range. 5 Valve (Part of thermo-chiller) Rc1/4 6 Y-strainer (#40) Rc1/2 7 Pressure gauge 0 to 145 psi (0 to 1 MPa) 8 Y-strainer (#40) or lter Rc3/4 Cable Specications Power supply and signal cable should be prepared by user.

port GA GC GD Rc BP unlocking port W GR GL GL1 Rc P Head side cylinder port GE B B2 H A S + Stroke H + Stroke A K AL C 4-FD K F GF BN Width across flats B1 4-J Cushion valve GB Effective thread length MM H1 V Q Fd E D D FY B MM Width across flats F FT FE T ZZ + 2 strokes VA N FX FZ Ee11 30 35 40 45 45 55 Effective thread length (mm) Width across flats A 22 30 35 35 40 40 B1 17 22 27 27 32

port GA GC GD Rc BP unlocking port W GR GL GL1 Rc P Head side cylinder port GE B B2 H A S + Stroke H + Stroke A K AL C 4-FD K F GF BN Width across flats B1 4-J Cushion valve GB Effective thread length MM H1 V Q Fd E D D FY B MM Width across flats F FT FE T ZZ + 2 strokes VA N FX FZ Ee11 30 35 40 45 45 55 Effective thread length (mm) Width across flats A 22 30 35 35 40 40 B1 17 22 27 27 32

(mm) Size Q1 = M Size 15 20 30 40 Q1 = M 15 20 30 40 Shaft type K T K T K T K T Thread Thread M3 x 0.5 2.5 2.5 2.5 2.5 M3 x 0.5 2.5 2.5 2.5 2.5 L1 = L1 = L1 M4 x 0.7 3.3 3.3 3.3 M4 x 0.7 3.3 3.3 3.3 L1 M5 x 0.8 4.2 4.2 M5 x 0.8 Q1 4.2 4.2 Q1 Symbol: A53 Shorten both long and short shafts. Applicable shaft type: K Symbol: A50 Shorten both long and short shafts.

Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 40 30 20 20 30 40 50 3. Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .

Maintain a minimum cylinder separation of 40 mm. 3. Pay attention to the length of time that a switch is on at an intermediate stroke position. When an auto switch is placed at an intermediate position of the stroke and a load connected to the auto switch is driven at the time the slide table passes, the auto switch will operate.

Note 15) For an actuator with lock, add the power consumption for the lock.

The Volume Flow of 9.44 l/min applies to an element (Valve, fining, tub etc.) with an equivalent orifice "S" of 1 mm'. lf an lement has for example an "S' ot 4,5 mm', the flow would be 4.5 times higher, in this case 4.5 . 54.44 limin = 245 Umln Example 2: Given an element wilh an 'S'ol 12 mm", a working pressure of 7 bar and an air consumption ot 600 ymin.

The Volume Flow of 9.44 l/min applies to an element (Valve, fining, tub etc.) with an equivalent orifice "S" of 1 mm'. lf an lement has for example an "S' ot 4,5 mm', the flow would be 4.5 times higher, in this case 4.5 . 54.44 limin = 245 Umln Example 2: Given an element wilh an 'S'ol 12 mm", a working pressure of 7 bar and an air consumption ot 600 ymin.

1.0 Communication speed [bps] 156 k/625 k/2.5 M /5 M/10 M 125 k/250 k/500 k 9.6 k/19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 M 10 M/100 M Configuration file Note 2) EDS file GSD file EDS file Communication specifications Input 896 points 108 words 4 stations occupied (8 times setting) Input 200 bytes Output 200 bytes Input 57 words Output 57 words Input 256 bytes Output 256

Ht BY IA 43 25 40 Max.Wc 36 35 13 D 30 Width across flats K Ws Width across flats 44 Clevis width CLK1A: 16.5 R15 0.050 0.093 +0.027 0 Shaft: 12d9 Hole: 12H8 F +0.3 0 +0.4 0 CLK1B: 19.5 Z + Stroke S + Stroke 1.5 27 2 40 57 97 ZZ + Stroke Approx.

40 40 25 36 36 38 NN 2 2 2 3 3 4 5 I 10 10 10 10 22 43 52 J 40 40 40 52 60 85 130 K 26.5 36.5 46.5 56.5 66.5 91.5 116.5 Note) Refer to "Dimensions" of MXS 12 on P. 58 for one with shock absorber as symmetric.

C -25 to +75 C -25 to +85 C ND9_E2/K05 -40 to +60 C -40 to +75 C -40 to +85 C ND9_E2/IK06 -40 to +60 C -40 to +75 C -40 to +85 C ND9_E2/B06 -40 to +60 C -40 to +75 C -40 to +85 C If the valve controller is already mounted on an actuator/valve assembly, operate the actuator into the closed or open position.

rod end fR [N] (40)1 (40)1 (40)1 (40)1 (100)1 0.5 89 W W W Rod (side) 10.0 (40)1 (40)1 (40)1 0.7 36 74 93 (40)1 0.3 33 37 26 54 69 Head ( side ) 0.5 39 25 27 19 41 52 C8525 C8520 0.7 32 20 22 15 33 43 1.0 Foot: M Rod flange: G Head flange: G (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.3 G G (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.5 W W Rod (side) W (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.7 (

H B C F A E G J K L D Size Tolerance +0.027 0 +0.027 0 +0.027 0 +0.027 0 +0.033 0 +0.033 0 +0.033 0 40 47 21 45 19 12 9 18 12 32 M8 x 20 60 R15 40 double clevis type 44 L K counter bore depth 2 J counter bore 50 53 23 50 23 12 11 21 14 35 M10 x 22 73 R18 50 double clevis type 53 A B 63 60 27 55 23 15 11 23 16 40 M10 x 25 80 R20 63 double clevis type 60 AC-A1bore size 80 67 31 65 28 16 13

Auto switch Nil Without auto switch Built-in Magnet Cylinder Model Bore size 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.

An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer.

Retainer prevents an accidental loss of needle.

K E O F F TA K EO F F T Y P E 1 "T" Type 4 "X" Type T H R E A D T Y P E Nil Rc(PT) N NPT P O R T S I Z E M5 M5 x 0.8 01 1/8 02 1/4 03 3/8 04 1/2 mm mm Model Port Size A B C Model Port Size A B C D Y11-M5 M5X0.8 8 12 8 Y14-M5 M5 23 16 14 25 Y21-01 1/8 10 29 19 Y24-01 1/8 40 40 22 40 Y21-02 1/4 10 29 19 Y24-02 1/4 40 40 22 40 Y31-01 1/8 11 33 19 Y34-02 1/8 49 43 28 48 Y31-02 1/4 11 33 19 Y44