Cooling Capacity: 250 (25 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: S (Conforming to CE/UL Standards)
Cooling Capacity: 250 (25 kW), Thread: Rc, Option: AK (A + K)
Cooling Capacity: 250 (25 kW), Thread: Rc, Option: S (Conforming to CE/UL Standards)
Cooling Capacity: 250 (25 kW), Thread: Rc, Option: AB1K (A + B1 + K)
Cooling Capacity: 250 (25 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AB1K (A + B1 + K)
Cooling Capacity: 250 (25 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKMS (A + K + M + S)
Cooling Capacity: 250 (25 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: KMS (K + M + S)
Cooling Capacity: 250 (25kW), Thread: Rc, Option: B1 (w/Earth Leakage Braker w/Handle)
Cooling Capacity: 250 (25kW), Thread: Rc, Option: S (Conforming to CE/UL Standards)
Cooling Capacity: 250 (25kW), Thread: Rc, Option: AS (A + S)
Cooling Capacity: 250 (25kW), Thread: F (G, w/Rc-G Conversion Fitting), Option: MST (M + S + T)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Cooling Capacity: 250 (25kW), Thread: Rc, Option: M (Applicable to DI Water Piping)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
35oC 20 15 10 5 0 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Fig. 9-18 Cooling Capacity (HRL200-W-40 CH1) HRL Series 9.4 Cooling Capacity 9-17 HRX-OM-X037 Chapter 9 Documents 9.4.13 HRL100/200-W-40 CH2 3.0 2.5 Cooling capacity [kW] Ambienttemperature 45oC or less 2.0 (Max. 1.5 kW) 1.5 Rated 1.0 kW 1.0 0.5 0.0 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Up to
Load weight Allowable moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
Load Weight Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
/Program No. selection 1 5 DI0 19 20 LZR LZ Encoder Z -phase pulse 23 DI1 Point table No.
Load weight Allowable moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]