Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: F [G(PF)], Port Size: 02 [1/4 (IR2000/3000)], Accessory: -, Temperature Environments: -, Suffix: -, Made to Order: -
Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: F [G(PF)], Port Size: 02 [1/4 (IR2000/3000)], Accessory: Bracket, Temperature Environments: -, Suffix: -, Made to Order: -
Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: F [G(PF)], Port Size: 02 [1/4 (IR2000/3000)], Accessory: Bracket+Gauge, Temperature Environments: -, Suffix: -, Made to Order: -
Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: F [G(PF)], Port Size: 02 [1/4 (IR2000/3000)], Accessory: Pressure Gauge, Temperature Environments: -, Suffix: -, Made to Order: -
Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: -, Temperature Environments: -, Suffix: -, Made to Order: -
Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: Bracket, Temperature Environments: -, Suffix: -, Made to Order: -
Body Size: IR3000, Type of Setting: 1 [Air Operated (Series IR2000/IR3000 Only)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: NPT, Port Size: 02 [1/4 (IR2000/3000)], Accessory: Bracket+Gauge, Temperature Environments: -, Suffix: -, Made to Order: -
Part Number Description: ADJUST SCREW IR2000-X40 Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 120 Family Description: IR PRECISION REGULATOR Class Code: 11 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number, ADJUST SCREW, IR2000-X40, AIRLINE EQUIPMENT, IR PRECISION REGULATOR, 11
M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C
A B A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
This will cause a malfunction.
lubricant that has a shielding effect from ozone.
IR1000-A, IR2000-A, and IR3000-A series precision regulators as well as IR1200-A, IR2200-A, and IR3200-A series regulators were released in August 2014.
NPT 23 (R,NPT) Nm 1/8 35 1/4 812 3/8 1520 1/2 2025 3/4 2830 1 3638 11/4 4042 11/2 4850 2 4850 () 1 5 VEX-OMV0001 VEX1 Series / () 5 () 30 ( ) 6 VEX-OMV0001 VEX1 Series (904 ) 3.57 () (AF )(AMAFM ) ( ) 22 3 JIS C 3306 0.5mm () () IR2000 A VEX1 B33 VK300-82-1 ITV VY AC100V 100V VK300-82-2-01 AC110V 110V VK300-82-2-03 AC200V 200V VK300-82-2-02 AC220V 220V VK300-82-2-04 ) AC240V 240V
The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3l/min). The amount of particle generation is measured for a specified number of operating cycles.