Drain cock Oil bowl B' C C Drain cock Drain guide (A) (B) Rc , NPT, G Mounting bracket Port size Model C B A Drain piping F G H J K L B' D E 6 6 1/4 female thread M3 x 0.5 1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121 55 63 83 96 96 116 1 4 3 8 , 56 75 102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth
Pressure gauge reverse mounted R Connection NPT 1/8 N01 Series IR2000 Connection NPT 1/4 N02 Connection NPT 3/8 N03 Connection NPT 1/2 N04 Connection G 1/8 F01 Connection G 1/4 F02 Connection G 3/8 F03 Connection G 1/2 F04 Series IR1000 Modular and Accessory Combinations Applicable model Description IR100--X120 IR200--X120 IR300--X120 1.
Normal condition (NOR): Flow measurement reference condition 101.3 kPa, 0 C. -55No.PF-OMJ0006-J Piping port specifications Model 01 02 N01 N02 F01 F02 C4 C6 C8 N7 4 8 6 1/4 (5/32") (5/16") Thread type (Port size) Rc Rc NPT NPT G G OneOneOneOne1/8 1/4 1/8 1/4 1/8 1/4 touch fitting touch fitting touch fitting touch fitting Straight without flow adjustment valve 95 g 125 g 55 g Bottom entry
(at 500 VDC) between terminals and case Standards CE/UKCA marked, UL (CSA) -21No.PF-OMJ0016-J Specifications of piping port Model 01 02 N01 N02 F01 F02 C4 C6 C8 N7 4 8 6 1/4 (5/32") (5/16") Thread type (Port size) Rc Rc NPT NPT G G OneOneOneOne1/8 1/4 1/8 1/4 1/8 1/4 touch fitting touch fitting touch fitting touch fitting Straight without flow adjustment valve 95 g 125 g 55 g Bottom entry
A T T 13 26 H L1 H L3 L1 (mm) (mm) When connected H Width across flats L1 L2 A 1 H Width across flats L1 A 1 T Connection male thread T Connection male thread Min. hole size Min. hole size Weight g Model Weight g Model Full length L3 KK130P-01MS -02MS -03MS -04MS KK130S(L)-01MS -02MS -03MS -04MS KK130S(L)-N01MS -N02MS -N03MS -N04MS 1 Reference dimension after installation R1/8 R1/4 R3/8 R1
Pressure gauge reverse mounted R Connection NPT1/8 N01 Series IR2000 Connection NPT1/4 N02 Connection NPT3/8 N03 Connection NPT1/2 N04 Connection G(PF) 1/8 F01 Connection G(PF) 1/4 F02 Connection G(PF) 3/8 F03 Connection G(PF) 1/2 F04 Series IR1000 Modular Products and Accessory Combinations Applicable model Description IR100 IR200 / IR2120 IR300 / IR3120 1 Air filter 2 Mist separator
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Note 2) Operation is possible with a valve with small Cv value when the operation cycle is small. 12 How to Order P B 1 3 1 3 A S Female thread / Tube extension P B 1 3 1 3 A S With nut Port size Material of diaphragm Symbol Main fluid Pilot air Symbol Material of diaphragm connection size connection size Female thread 1 PTFE 01 Rc 1/8 N01 NPT 1/8 F01 G 1/8 Actuation Tube extension Symbol
Note 3) The handle of the selector (2 position) cannot be removed or replaced alone. 5-6-35 Series VZM400 How to Order S 01 01 0 VZM45 Option Suffix for actuator F Foot bracket (Only internal pilot) Actuator type R S G B Red Hard steel roller Port size Basic 00 Color of push botton selector Rc 01 1 8 NPT N01 1 8 G F01 1 8 Roller lever 01 Black One Way Roller Lever 02 Green Straight plunger
Avoid using a switch in a magnetic environment. It may cause a malfunction. 2. Use a screwdriver of a size suitable for the groove of the adjustment screw. 2. Do not use in such an environment, where water or oil is splashed.
Note 3) The handle of the selector (2 position) cannot be removed or replaced alone. 5-6-41 Series VZM500 How to Order S 01 01 0 VZM55 Option Suffix for actuator F Foot bracket Actuator type R S G B Red Hard steel roller Port size Basic 00 Color of push button selector Rc 01 1 8 Roller lever 01 Black 1 8 NPT N01 One way roller lever 02 Green G F01 1 8 Straight plunger 05 Y Yellow Roller plunger
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove.
The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2", "H_2".
Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: 01 (R1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: 01 (R1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]