SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-V-01-A1"

Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5

Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: (None), Exhaust Solenoid Valve: V124-5LU-M5

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: -

B.B-BE 6:i% \@V @ @ F::] _ iElllEFffil El ffi L ] [PirsP l,dtm $epies LJ{ CmE[tUfrult Series LCOC Connecting Example . Power Connector Molex lnc. part numbr 39-01-2180 (receptacle), 39-00-0039 (pins).

Valve power PWR(V) supervision Enable Disable Enable WARNING: If safe PWR(V) monitoring is required for the application or if PWR(V) diagnostic is disabled on the device PWR(V) failures must be managed externally by other means.

/ sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 11-3 Block diagram of the EX245-DX1 74 No.EX##-OMY0004 12.

DO (n+1) 0 V DO (n) FE / Shield Output interface Output interface Short circuit Short circuit protection protection Output circuit / Output circuit / Bus interface Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 12-3 EX245-DY1 79

PF-OMK0003CN-E A 1L(2) L () M315L L () / ZS-36-A1 1 L (2 ) (M315 L)2 ZS-36-A2 2 L (2 ) (M325 L)2 ZS-36-A3 3 L (2 ) (M335 L)2 ZS-36-A4 4 L (2 ) (M345 L)2 ZS-36-A5 5 L (2 ) (M355 L)2 -11No. PF-OMK0003CN-E DIN -12No. PF-OMK0003CN-E F 15[V]F.S.=5-1=4[V] (1%F.S.=40.01=0.04[V]) F.S. (full spanfull-scale) 90 -13No. PF-OMK0003CN-E 3%F.S.

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)

Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: (None 75 dB), Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5

Blue (DC(-)) 3 Blue (DC(-)) Other Settings Black (OUT: 4 to 20 mA) 4 Black (OUT: 1 to 5 V) Blue (LINE(-)) Auto shift [Default setting] Auto shift zero Mounting and Installation Check that the above preparation has been performed correctly, then part A shown should be pressed in by hand to make temporary connection.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation