VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.
Station 2 52 43 Station 20 340 331 Station n L1 L2 3 68 59 4 84 75 5 100 91 6 116 107 7 132 123 8 148 139 9 164 155 10 180 171 11 196 187 12 212 203 13 228 219 14 244 235 15 260 251 16 276 267 17 292 283 18 308 299 19 324 315 43 Series SYJ5000 Flat Ribbon Cable Manifold [ ]: AC SS5YJ5-20PStations -00 For (Built-in one-touch fitting) N3 N7 C4 C6 Manual override L1 L2 M5 x 0.8 (A, B port)
Input Discharge stop signal 50 ms or more 50 ms or more The error signal can be reset by turning the reset signal on and then off. ON OFF Input Reset signal Discharge signal (on when ions are being generated) ON OFF Output ON OFF When an error occurs, the signal is turned off. Output Error signal Error occurred Ions are still generated even when the maintenance signal is turned on.
(Effective energizing time is over 67 ms at 24 VDC.)
Nil Applicable blanking plate assembly SYJ300-10-2A 02 2 stations Pilot valve is on the A port side.
L1 79.5 6.5 P=25 65.5 72 R4.5 46 Mounting hole for 2-M5 B A B A A A B A B A B A 9 A A A A A A A 143 163 42 80 34.5 R4.5 B B 9 B B B 55.5 SI unit 10 101 Stations D-side U-side 1 2 3 4 5 6 7 8 n Formulas L1 = 25n + 106 (Maximum 16 single wiring stations) L2 = 25n + 192 n: Stations n L L1 L2 1 131 217 2 156 242 3 181 267 4 206 292 5 231 317 6 256 342 7 281 367 8 306 392 9 331 417 10 356 442
= 41n + 96 n: Stations (Maximum 12 stations) Formula: L1 = 41n + 76, L2 = 41n + 96 n: Stations (Maximum 12 stations) L n Dimensions 2 158 178 9 445 465 2 158 178 9 445 465 3 199 219 10 486 506 3 199 219 10 486 506 4 240 260 11 527 547 4 240 260 11 527 547 5 281 301 12 568 588 5 281 301 12 568 588 6 322 342 6 322 342 7 363 383 7 363 383 8 404 424 L1 L2 8 404 424 L1 L2 2-6-37 Base Mounted
AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Adjustment of Cushion Effect (Smooth Start-up, Soft Stop) Caution Since the external slider and piston slider are directional for size 10, refer to the drawings below when performing disassembly or maintenance.
Series ZA Compact Vacuum Ejector ZA ZX ZR ZM ZMA ZQ Total length Total width ZH 72.9 mm 9.9 mm 72.9 mm 9.9 mm ZU ZL ZY ZF ZP Total height SP 52.5 mm 52.5 mm ZCUK AMJ AMV AEP Mass 50 g 50 g HEP Related Possible to be mounted on moving parts thanks to lightweight Supply pilot valve Equipment Response time Response time 40 ms 40 ms Normally closed Latching Release valve Response time for
Flange: (N)CQ2KWF/(N)CDQ2KWF CQ2 Rod End Male Thread Without auto switch With auto switch L2 Bore size (mm) A1 107 117.5 119 L3 M FV A1 117 127.5 129 40 50 63 38.5 43.5 43.5 28.5 33.5 33.5 FX FZ 4 x FD FT L1 B + Stroke L2 + Stroke NCQ2 Rod End Male Thread A + 2 (Stroke) Without auto switch With auto switch L2 L3 Bore size (mm) A1 A1 Rod end male thread 40 50 63 96 105.5 107 106 115.5 117
R Right side (PV port on the right side) L Left side (PV port on the left side) 02 2 B Both sides (PV port on both sides) Nil All stations 1 Station 1 only 08 8 1 Viewed from the front side of valve unit, confirm the port location on the right and/or left side. 2 EXH ports are released to atmospheric pressure in both sides.
Model Allowable Moment (Nm) Allowable dynamic moment Model Mounting orientation Load movement direction LTF6 200 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep L1 (mm) Pitching 100 m a=1000 a=2000 a=3000 L1 30 20 10 0 Transfer load m (kg) L2 200 a=1000 a=2000 a=3000 Mer L2 (mm) Rolling Yawing 100 m L2 Mer 30 20 10 0 m Transfer load m (kg) 200 a=1000 a=2000 a=3000 L3 (mm) 100
###-##-L3/L4#-### PNP output type PF2MC7###-##-B#-### PNP 2 outputs PF2MC7###-##-L2#-### PNP (1 output) + Analogue output type PF2MC7###-##-L3/L4#-### -28No.PF-OMZ0002-A Outline of Settings [Measurement mode] Power is supplied The output will not operate for 3 seconds after supplying power.
112.2 132.6 122.4 L1 L2 Bracket mounting (For bottom ported) Upward connector Panel fitting dimensions/Mounting hole dimensions M3 x 0.5 recommended 33 30 L1 L2 3 Station n 1 2 3 4 5 6 7 8 9 10 11 12 61.2 36 71.4 46.2 81.6 56.4 91.8 66.6 102 76.8 112.2 87 122.4 97.2 132.6 107.4 142.8 117.6 153 127.8 163.2 138 173.4 148.2 L1 L2 Lateral connector Panel fitting dimensions/Mounting hole dimensions
show the connector pin layout. -24No.PF-OMY0002 Example of wiring for accumulated pulse output NPN output type PFMC7###-##-L#-### NPN 2 outputs + Analogue output type PFMC7###-##-L2#-### NPN (1 output) + Analogue output type PFMC7###-##-L3/L4#-### PNP output type PFMC7###-##-B#-### PNP 2 outputs PFMC7###-##-L2#-### PNP (1 output) + Analogue output type PFMC7###-##-L3/L4#-### -25No.PF-OMY0002
Name of terminal block (LED) Note VQZ POWER RUN SD RD ERR RUN ERR TRD 10 1 VQD 24V 0V + + FG L1 L2 SG L1 L2 SG 24V 0V Description ON when power supply is ON LED Description LED POWER Lights when transmission is normal and PLC is in operation mode RUN Lights when power is ON and slave stations are operating normally RUN T/R ERR Blinks during data transmission/reception ON when transmission
L1=10.5n+14.5 L2=10.5n+25 n: Station (Max. 16 stations) Equation= Dimensions/Side entry connector [PS] (mm) Cylinder port is located at U side of body.
398 387.5 376 11 20 423 412.5 392 15.5 L1 L2 L3 L4 3-3-93