SMC Corporation of America
Elite Part Number Search
Search Results "JAHF63-24-200"

9-12 9.4.3 HRL300-A-40 CH1 . 9-13 9.4.4 HRL100/200/300-A-40 CH2 . 9-13 9.4.5 HRL100-A-40-T2 CH1 . 9-14 9.4.6 HRL200-A-40-T2 CH2 . 9-14 9.4.7 HRL300-A-40-T2 CH1 . 9-15 9.4.8 HRL100/200/300-A-40-T2 CH2 . 9-15 9.4.9 HRL300-A-40-T3 CH1 . 9-16 9.4.10 HRL300-A-40-T3 CH2 . 9-16 9.4.11 HRL100-W-40 CH1 . 9-17 9.4.12 HRL200-W-40 CH1 . 9-17 9.4.13 HRL100/200-W-40 CH2 . 9-18 9.4.14 HRL100-W-40-T2 CH1

VX2 24 VDC GDM2A-G-S5 100 VAC VXK 110 VAC 200 VAC VXD None 220 VAC GDM2A-R 230 VAC VXZ 240 VAC 24 VAC VXS VXS 48 VAC 24 VDC GDM2A-G-Z5 100 VAC GDM2A-R-L1 110 VAC GDM2A-R-L1 200 VAC GDM2A-R-L2 220 VAC GDM2A-R-L2 230 VAC GDM2A-R-L2 240 VAC GDM2A-R-L2 24 VAC GDM2A-R-L5 48 VAC GDM2A-R-L5 VXB VXE With light VXP VXR VXH VXF Gasket Part No. for DIN Connector VCW20-1-29-1-F VX3 VXA Bracket Assembly

Ground the F.G. cable with a resistance of 100 or less +24 V +24 V Brown (2 pcs.) +24 VDC +24 V +24 V +24 V Brown (2 pcs.) +24 VDC +24 V +24 V +24 V 0 V 0 V DC/DC Power supply 24 VDC Power supply 24 VDC Blue (2 pcs.) 0 V 0 V 0 V DC/DC 0 V Blue (2 pcs.) 0 V 0 V F . G. F . G.

3-M3 x 0.5 28 3-M3 x 0.5 G Width across flats 24 10 E 10 ZX F F E ZR Y Y 6 3 ZM 18 18 C C ZH A A B D B D ZU Dimensions Dimensions A (mm) ZL (mm) Model Model A B C D E F G Y B C D E F G Y ZY ZPT40HB-B8 ZPT40HB-A14 M8 x 1.25 40 41.4 28.4 43.2 20.5 32 62 13 40 41.4 28.4 43.2 20.5 32 13 ZPT50HB-A14 -B10 M10 x 1.5 50 51.9 35.7 54 24 35.5 65.5 16.5 ZQ ZPT50HB-B8 M8 x 1.25 50 51.9 35.7 54 24 35.5

VDC ZNR ZNR 12 to 24 VDC SOL DC () 100 to 200 VAC SOL 2 DC () ZSE ISE 2 ( ) PNP open collector output Conduit terminal DIN type connector With indicator light AC Circuit Conduit terminal With indicator light DC circuit PSE DC (+) 1 ( ) 1 DC (+) MAX 80 mA Rectifying device Z I SE3 OUT Load 12 to 24 VDC ZNR ZNR 100 to 200 VAC 12 to 24 VDC SOL SOL DC () PS 2 ( ) LED 2 DC () indicator light

LED: Light emitting diode R: Resister NL: Neon bulb R: Resister 4-14-23 Base Mounted 24 Series VQZ100/200/300 Precautions Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 4-18-2.

Core wire color Brown: 24 VDC +10%/5% (For output) White: 0 V (For output) Blue: 24 VDC10% (For control and input) Black: 0 V (For control and input) Gray: Not connected Terminal no.

Application Relay, PLC Relay, PLC 24 VDC relay, PLC 24 VDC relay, PLC IC circuit, Relay, PLC IC circuit, Relay, PLC Type Load voltage 24 VDC, 100 VAC 24 VDC, 100 VAC, 200 VAC 24 VDC (10 to 28 VDC) 24 VDC (10 to 28 VDC) 28 VDC or less 28 VDC or less Load current range Indicator light Auto switch part no.

Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).

1.5 13 36 19 15 21 40 to 800 24 24 41 18 21 14 11 54 10 11 48 7.5 9 35 158 6 55 75 M16 x 1.5 19 44 24 21 21 (mm) Foot bracket plate thickness is dimension LT + 1mm.

Metal ( shaded) part Metal ( shaded) part Tap for ground wiring Resin part ( shaded) 454 Ionizer IZN10 Series Power Supply Cable Connection Circuit NPN PNP Ionizer Ionizer IZS Brown +24 VDC Brown +24 VDC +24 V +24 V Power supply 24 VDC 10% 0 V +24 V Power supply 24 VDC 10% 0 V +24 V Blue 0 V Blue 0 V IZN IZN INPUT PLC OUTPUT OUTPUT PLC INPUT IZF Orange Discharge stop signal Orange Discharge

30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/

kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting

Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,

Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Note) For the special voltages, please consult with SMC.

Standard stroke Long stroke L1 14 15.5 18.5 22.5 Bore size (mm) 12 16 20 25 H1 C1 X L1 24 25.5 28.5 32.5 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 9 10 12 15 10.5 12 14 17.5 Basic Style Long stroke range (mm) 35 to 100 35 to 100 75 to 200 75 to 300 Standard stroke range (mm) 5 to 30 5 to 30 5 to 50 5 to 50 Long stroke Standard stroke Without auto switch With auto switch A 20.5 20.5 24 27.5 Bore

D-F9BAL Symbol A B W HS CQ2 Double acting: single rod, Single acting: single rod/spring return, spring extend 4.5 3.5 14.5 16.5 12 MU Bore size (mm) 5 3 15 18.5 16 9 6.5 11.5 22 20 10 8.5 9.5 24 25 Long stroke 8 10 16.5 8 12 8.5 9.5 8.5 18.5 16 Bore size (mm) 12 15 22 3 20 13 17 1 24 25 Anti-lateral load 9 4 14 16.5 12 8.5 4.5 13.5 18.5 16 Bore size (mm) 12 8.5 9.5 22 20 13 10.5 7.5 24 25

Stations are counted starting with station 1 on the D side. 60P Flat cable type (26 pins) Without power supply terminals With power supply terminals Positive common Negative common Common 26 26 26 Pos. pin Pos. pin (common) 25 25 25 SOL.B 24 24 Neg. pin (common) Neg. pin Station 12 24 23 23 SOL.A 23 Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor