The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 12.58839 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 10.14126 lb
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single Phase 100-115V, Position Detection: Absolute, Motor Type: AC servo motor (S6), Controller/driver type: Pulse input type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single-Phase 200-230V, Position Detection: Absolute, Motor Type: AC servo motor (S6), Controller/driver type: Pulse input type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single Phase 100-115V, Position Detection: Absolute, Motor Type: AC servo motor (S6), Controller/driver type: CC-Link direct input type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single-Phase 200-230V, Position Detection: Absolute, Motor Type: AC servo motor (S6), Controller/driver type: CC-Link direct input type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single Phase 100-115V, Position Detection: Absolute, Motor Type: AC servo motor (S6), Controller/driver type: SSCNET III type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: AC Single-Phase 200-230V, Position Detection: Absolute, Motor Type: AC servo motor (S6), Controller/driver type: SSCNET III type
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: H (High Precision), Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)