SMC Corporation of America
Elite Part Number Search
Search Results "LEY32B-250B-S5"

Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5)

Table Accuracy: Basic, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length

Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable

Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length for

Table Accuracy: High Precision, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length

Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length

Table Accuracy: High Precision, Size: 10, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length for

Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.22, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator cable length(m): 5, Controller

Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.32, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator cable length(m): 5, Controller

Oscillation Angle A: 320°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 10, Size: 50, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator

Series: LEFS, Accuracy: Basic Type, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 250mm, Motor Option: B (w/Lock)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Size: 32, Bearing Type: Sliding Bearing, Motor Mounting Position: In-line, Motor Type: AC Servo Motor, Absolute Encoder, Output 200W, Lead: LEY25 6mm; LEY32 8mm; LEY32 Top Mount 10mm, Stroke: 250mm, Motor Option: with Lock, Guide Option: -, Cable Type: -, Cable Length: -, Driver Type: -, I/O Connector: -