P1 70W XGT Kalrez Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 3310-75 To order something else Nil (standard), list the symbols starting with X, followed by each symbol for "body surface treatment", "seal material" and then changed parts at last. CYV Chemraz Example) XLAQ-25-M9NA-XAN1A VMQ FKM for Plasma ULTIC ARMOR U1 UA4640 Produced by Mitsubishi Cable Industries, Ltd.
. + 4 x (n pcs. 1) 360.3 360.3 360.3 4 x R3 or less 4 x R3 or less 33 ZSE20(F)/ISE20 Series Function Details ZSE20C(F)/ISE20C(H) ZSE20B(F)/ISE20B ZSE20B(F)-L/ISE20B-L ZSE20A(F)/ISE20A ZSE20(F)/ISE20 Function Details Display examples of the main and sub (set value) screens of each mode.
O 1 (O P71) V (V P71) 6/12 FGX-OM-L009-B FGESL Series IN/OUT -0.1MPa (P10) (M12) IN OUT O O V 40 () () () 7/12 FGX-OM-L009-B 1 G1/8 () (R1 R2) IN (Rp1/4) (R3/4) DRAIN OUT (Rp1/4) (R1 R2) (R3/4) 1 1 SUS304 O FGE-OP007 8 NBR FKM O (NBR) (FKM) M10X1.5 1 SUS304 M10 SUS304 SUS304 SUS316WPA FGE-OP005 SUS316 SUS304 SUS304 FGD-OP001 SUS316 FGE-KT001 NBR O FGE-KT002
R3 3 (29) 32 ( 35) 29 5 37 (45) 5 MQR8-F MQR12-F 4-6 counter bore 5 4-3.2 through P.C.D.48 4-8 counter bore 5.5 4-4.5 through32 drill through 4-4.5 through 2-4.2 through 3 *at 2 points 27 drill through 45 25 R4 R4 45 3.5 (43) 41 5 (55) 7 45 ( 50) 46.5 4 Series MQR Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Port size 6 8 10 12 Flow valve Pressure valve ASR4 3 0F02 ASR53 0F02 ASR53 0F03 ASR6 3 0F03 ASR6 3 0F04 ASQ4 3 0F02 ASQ53 0F02 ASQ53 0F03 ASQ6 3 0F03 ASQ6 3 0F04 R1/4 R1/4 R3 /8 R3 /8 R1/2
Male thread type A2 A1 T D H L1 L2 (mm) A1 A2 Effective area mm L2 Body size H Width across flats T Connection male thread Minimum bore Model D Weight g When When L1 connected connected KKH3S-01MS R1/8 33.5 20.4 20.4 6 36 18.2 14 1/8 40 37.5 KKH3S-02MS R1/4 31.5 19.5 21.1 9 34 KKH4S-01MS R1/8 54.1 50.4 46.4 48.8 22.9 6 50.1 KKH4S-02MS R1/4 54.7 51 19 45 45.4 38.9 9 48.7 25.4 1/4 KKH4S-03MS R3
Rc1/2 1) R3/4: 28 30Nm R1/2 ,R3/4 2. 3. (27mm)(22mm) () () () 12-4 1. (1 ) 2. 3. 0 12 2 13 R 13 R R (GFCI) GFCI 1 GFCI 13-2 13-1 1. 2. 3. 4. GFCI 5. 6. 7. 13 1 13 R 13-2 IDFA6E-20-R 5A 30mA 13-3 1) 2) 3) 9.5mm M5 1.25mm 2 L N 6.5mm M3 1.25mm 2 6-3 14-3 13 2 14 T 14 T T 14-2, 14-3 14-1 1. 2. 3. GFCI 4. 5. GFCI 6. 7. 8. 9.
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
AHC System Series MA2 How to Order AHC unit AHC unit MA 210 Y M3 N R3 Tool adapter Robot adapter Without robot adapter 8 10 11 14 15 20 Nil S1 R1 R2 R3 R4 R5 Auto hand changer Air gripper for AHC Applicable shaft diameter Transportable mass Transportable mass 3 kg 2 AHC unit Electric specifications Air connection size M3 M3 x 0.5 None N Air gripper for AHC Tool adapter <10/15> MA 210 A M3
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 15.21189 lb
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Type: Step Motor (Servo/24 VDC), Lead: A (LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 200mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 3 (3m)
Size: 25, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32, 16), Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Size: 25, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector or I/O
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 16, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 10mm; LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm, Stroke: 200mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 3m, Controller Type: -, I/O Cable Length
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32, 16), Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 7.05479 lb, ModelStroke [mm]Product weight [kg]Step motorServo motorLEY32D302.49?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting