SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2B10-400-C80"

Supply voltage Internal voltage drop of switch > Minimum operating voltage of load 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator for right (MODEL D-A6/A80/A80H/A90/A90V/C80/R80/90/E80A/ Z80) 3) Generally, the internal voltage drop will be greater with a 2wire solid state auto switch than with a reed switch

. <> 6080 D-M9A(V) M3M3 0.60.7Nm (M2.5) (M2.5)0.050.1Nm 56mm 1)(M2.5) 2)M3 BMA3 A 12 4 1) (BMA2-A)(BJ5-1/) () 2) (BMA2-AS/)(BJ4-1/) D-M9A(V) () BBA3:D-B5,B6,G5,K5 BBA4:D-C7,C80,H7 3)BBA3 Best Pneumatics No. P1357 D-H7BA,G5BA BBA3,BBA4 5 (30%) 13 14 () (mm) 1) () 2) 6. 15 7 Best Pneumatics No. P.12631371 Best Pneumatics No.

Rail mounting Grommet CDJ2QB16-60-A C73 C80 C73C C80C 100V 12V Band mounting CDJ2QB10-45-B No IC 100V 5V, 12V Relay PLC 2 wire Yes 24V 12V Connector No 24V 5V, 12V IC Diagnostic indication (2 color) Grommet Yes H7A1 H7A2 H7B H7C H7NW H7PW H7BW F79 F7P J79 3 wire (NPN) IC 5V, 12V Grommet 3 wire (PNP) 2 wire 12V Connector 3 wire (NPN) F79W F7PW J79W 5V, 12V IC Diagnostic indication (2 color

Supply voltage Internal voltage drop of switch > Minimum operating voltage of load 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator for right (MODEL D-A6/A80/A80H/A90/A90V/C80/R80/90/E80A/ Z80) 3) Generally, the internal voltage drop will be greater with a 2wire solid state auto switch than with a reed switch

Auto switch type Indicator light Wiring (output) Electrical entry Applicable load Type Special function Rail mounting 5 (Z) None (N) Band mounting 0.5 (Nil) 3 (L) DC AC Perpendicular In-line 3-wire (NPN) C76 A76H 5V IC circuit Yes A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV A72H A73H A80H Grommet 200V Reed switch Solid state switch Rail mounting type CDJ2XB10-45-A Example C73 C80

C76 5V IC circuit Yes C73 C80 B53 B54 B64 C73C C80C A33A A34A A44A 12V 5V, 12V 12V 12V 12V 12V 5V, 12V 12V 100V 100V or less 100V, 200V 200V or less 24V or less Relay PLC No Grommet IC circuit PLC Reed switch Yes No Yes No Relay PLC 2-wire 24V Connector IC circuit PLC Terminal conduit 12V 100V, 200V Yes Relay PLC DIN terminal Diagnostic indication (2-color display) B59W Grommet

Applicable Auto Switches: Lead wire length (m) Load voltage Indicator light Wiring (output) Special function Auto switch type Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC C76 B53 B54 B64 C73 C80 C73C C80C IC circuit 5V 3-wire (NPN equiv.)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: C80, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 63, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: C80, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 70, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: C80, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 73, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: C80, Lead Wire Length

Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: C80

Mounting: Basic Style, Bore Size: 32mm, Port Type: Rc, Stroke: 1000mm, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: -

Mounting: Basic Style, Bore Size: 32mm, Port Type: Rc, Stroke: 1000mm, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Mounting: Basic Style, Bore Size: 40mm, Port Type: Rc, Stroke: 1000mm, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Mounting: Basic Style, Bore Size: 20mm, Port Type: Rc, Stroke: 1000mm, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 15mm, Cylinder Rod Motion: Normally Retracted, Valve Specifications: 24VDC L Plug Connector, Light & Surge Suppressor: Light & Surge Suppressor, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: 1 pc.


Note) The following auto switches are reed auto switches without an indicator light (only the reed switch is built in): D-A67 (L), D-A80 (L), D-A80H (L), D-A90 (L), D-A90V (L), D-C80 (L), D-E80A (L), and D-Z80 (L).

Band Mount: C80--Reed, 24V to 100V AC/DC, Rail Mount: None, Tie-rod Mount: None, Direct Mount: None, Lead Wire: Z (5m)