O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.
Flow Rate and Sonic Conductance Model AS1002F-mA AS2002F-mA AS2052F-mA AS3002F-mA AS4002F-mA Tubing O.D.
Model number: HRS040-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Model number: HRS050-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" 38 (1.33) 7 (0.25) Flow rate l/min (ANR) (CFM) 12 (0.42) Controlled flow 0.6 (0.03) 0.2 (0.01) 0.1 (0.006) Effective area
Male Rod End F . Female Rod End B .
lead Series Series 6 Nil X10 F H L 6 8 Standard motor 6mm Cable length Non-standard motor 10mm Series 8 2 3 4 5 2m 20mm Motor specification 3m Motor output Nil G R Y Standard motor 4m Brake Matsushita Electric Industrial Co., Ltd. 5m Nil K E F Mitsubishi Electric Corporation 100W None Switch specification Yasukawa Electric Corporation 200W With brake Nil 1 2 3 4 5 6 7 A B Without switch
Field name Example RTU mode ASCII mode (HEX) character data binary data Header : None Device address 0x01 0,1 0x01 Function 0x04 0,4 0x04 Quantity of bytes to read 0x02 0,2 0x02 Information of 0009h(Data display 1) 0x00FA 0,0,F,A 0x00,0xFA Checksum ASCII:LRC RTU:CRC F,F 0x39,0x73 Trailer CR/LF None Total quantity of byte 15 7 * Response message at an ambient temperature of 25.0C 3.13 Register
tubing 3.18/2 Coil voltage 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Electrical entry G Grommet C Plug lead with light/ surge voltage suppressor Power consumption Pressure specification Flow rate Power consumption (W) Maximum operating pressure (MPa) 0.1 0.3 0.3 0.5 0.1 0.3 Cv factor Symbol 0.021 0.011 0.021 0.011 0.011 0.006 A B C D E Note) 0.35 0.5 0.1 (With power saving circuit) F
(C or F). Read the circulating fluid discharge temperature which is displayed on the touch panel.
Direction of detecting axis, Perpendicular to detecting axis: 0.04mm or less Repeatability 12 to 24V DC 10%, Ripple P-P 10% or less Power supply voltage Current consumption 15mA NPN Maximum load current: 100mA Maximum applied voltage: 30V DC Residual voltage: 1V or less (At 100 mA inrush current) 0.4V or less (At 16 mA inrush current) Output Courtesy of Steven Engineering, Inc.-230 Ryan Way
N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119
How to Order KQ2 H 05 S 02 With thread seal One-touch fittings Nil Without seal S With thread seal Applicable tubing O.D.
These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting in the following formula. f = k x v f: Frequency of vortexes, v: Flow velocity, k: Proportional constant (determined by the vortex generator's dimensions, shape, etc.) Therefore, the flow rate can be measured by detecting this frequency.
C (F) note 2 -5~+50 (+23~+122) -20~+60 (-4~+140) Max.
Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.
AC adapter (Without AC cord) 03 Power supply cable (For 24 VDC wiring) N None Symbol Type 01 Standard nozzle 02 Bypass nozzle*3 *1 The AC adapter body and the power supply cable (For AC adapter) come as a set.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)