Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: Analog 4 to 20mA 2
Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: Analog 4 to 20mA 2
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
OO 3.24 5 . 1 2 8.01 Techn Vacuum System Specification (continued) 2.
, 10 34, 1 95 50 50 H O W T O O R D E R ( N ) A K 2 0 0 0 S E R I E S 000 (N)AK P O R T S I Z E M O D E L 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 P O R T T H R E A D 2 1/4 4 1/2 6 1 Nil Rc(PT)* N NPT F G(PF)* * Remove N when ordering Courtesy of Steven Engineering, Inc. !
5.75 AFW450-N20DG-[a] 765 EL-AFW150-[a] 450 12.5 1/2 1/4 2 1.5 6.5 26.75 5.75 AFW650-N20DG-[a] 1,105 EL-AFW150-[a] 650 32 1/2 1/2 3 1.5 7 27.5 9 AFW1000-N30DG-[a] 1,700 EL-AFW150-[a] 1,000 33.5 1/2 1/2 3 1.5 7 32.5 9 AFW1250-N30DG-[a] 2,125 EL-AFW150-[a] 1,250 E 33.5 1/2 1/2 3 1.5 7 38.5 9 AFW1500-N30DG-[a] 2,550 EL-AFW150-[a] 1,500 [a] Element grade, specify E5 (5 m), EA (0.01 m), or EC
2 except !0. Note 2) Part no. for bowl assembly: AD34 Note 3) Part no. for bowl !
M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge
Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)