SMC Corporation of America
Elite Part Number Search
Search Results "PSE563-A2-28"

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: N02 [NPT 1/4 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: Rc 1/8, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Please keep this manual handy for future reference. 3 Bit: 7 0 Byte 2 Offset 3 TDTransmit Data RDReceive Data 4 2 Bit: 7 0 Byte 3 Offset BUS IN: M12 4-pin socket D-coded 1 Bit No. 6 4 6 4 2 0 0 0 Designation Description No. 4 Solenoid on side A 2 4 6 16 28 30 0 8 Output No. 2 1 TD+ Transmit Data + To obtain more detailed information about operating this product, please refer to the SMC website

Fieldbus interface connector layout 6 SF BF L/A1 PWR L/A2 PWR(V) BUS OUT: M12 4-pin socket D-coded (SPEEDCON) 1 No. Designation Description 4 1 TD+ Transmit Data + LED Status Description 2 Thank you for purchasing an SMC EX260 Series Fieldbus device (Hereinafter referred to as "SI unit" ).

Element Description Safety Instructions S/E ST L/A1 PWR(V) L/A2 Fieldbus interface connector (BUS OUT/Port2) 1 POWERLINK connection PORT 2 (M12 4-pin socket, D-coded) LED Status Description These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Cylinder (including thin round plate) Position of rotational axis: Through the plate's central axis Position of rotational axis: Perpendicular to the shaft anywhere along its length I = m1 x + m2 x 3 a1 3 a2 I = m x 2 r 2. Thin shaft Position of rotational axis: Through the shaft's center of gravity 7.

Proper tightening torque Nm Connection thread size 7 to 9 NPT 1/16, NPT, R1/8 12 to 14 NPT, R1/4 22 to 24 NPT, R3/8 28 to 30 NPT, R1/2 2. When a fitting is over tightened, more of the sealant material is squeezed out. Remove the squeezed out sealant material. 3. When tightening is not sufficient, it will cause sealant failure or a loose fitting. 4.

Cylinder (including thin round plate) Position of rotational axis: Through the plate's central axis Position of rotational axis: Perpendicular to the shaft anywhere along its length I = m1 x + m2 x 3 a1 3 a2 I = m x 2 r 2. Thin shaft Position of rotational axis: Through the shaft's center of gravity 7.

PSE561 is for low vacuum (-101 to 0 kPa), while PSE563 is for compound pressure (-100 to 100 kPa).  The accuracy and construction are suitable for general purpose applications.  Includes a fixed cable with field wired connector option.  PSE561 and PSE562 are UL/CSA, CE and RoHS compliant, with IP65 enclosure ratings.

PSE561 is for low vacuum (-101 to 0 kPa), while PSE563 is for compound pressure (-100 to 100 kPa).  The accuracy and construction are suitable for general purpose applications.  Includes a fixed cable with field wired connector option.  PSE561 and PSE562 are UL/CSA, CE and RoHS compliant, with IP65 enclosure ratings.

Example: -XA2A24C1C30 -XA2C1C4C30 104 Rotary Actuator: Free Mount Type Series CRBU2 Axial: Top (Long shaft side) Axial: Bottom (Short shaft side) Symbol: A2 Symbol: A1 The short shaft can be further shortened by machining female threads into it. The long shaft can be further shortened by machining female threads into it.

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type]

Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]