temperature 40C (200 VAC) Set temperature range 10 to 30C Temperature stability 2.0C 615 Maintenance free Magnet pump Low-noise design 55 dB (A) Power supply 100/200 VAC 50/60 Hz 230 VAC 50/60 Hz 191 Thermo-chiller Basic Type HRSE Series Circulating Fluid Temperature Controller Simple function and performance Cooling capacity 1.2, 1.6, 2.2 kW (60 Hz) Power supply 100/200 VAC (50/60 Hz) 230
1 Vacuum Pad Series ZP Non-rotating 2 to 8: Stroke 6, 10, 15, 25 mm 10 to 32: Stroke 10, 20, 30, 40, 50 mm 40, 50: Stroke 10, 20, 30, 50 mm Type Without buffer With buffer VAC VAC Vacuum entry port Mounting Vacuum entry port Mounting ZX 13-11-2 to 13-11-27 VAC VAC Buffer body Female thread Female thread Male thread Series (Common) ZR ZPT Barb fitting VAC Barb fitting Buffer body ZM Vertical
and 115 VAC, and between 220 VAC and 230 VAC.
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
Note) Breathing hole (M3 x 0.5) 3.7 3.7 13.7 1 SUPz VACz OUT port (4, 5/32") SUP, VAC port (4, 5/32") OUTx 3 EXHc ATMc 2 5 EXH, ATM port (4, 5/32") 38 2-M3 x 0.5 thread depth 3.5 Bracket mounting hole L-bracket (Option) Flat bracket (Option) 6-3.5 19 74 2-3.5 19 27 19 64 Minimium bending radius 80 28 Body +50 0 3000 15 35 (30.9) 4 8.7 9.9 Cable connector (4-wire) Straight type (Option) 7
D-Y7GL Motor model Compatible driver model Power supply voltage (VAC) Motor output (W) + Brown lead wire 100/115 MSD011P1E MSM011P1A Matsushita Electric Industrial Co., Ltd.
With brake: 150 Without brake: 115 Housing 36.5 32 Thread size M4 x 0.7 6 4 70 M5 x 0.8 6 4 70 Effective thread length (mm) Quantity P.C.D. B 89 A A B Section BB Coupling P.C.D.
and 115 VAC, and between 220 VAC and 230 VAC.
Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.
50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override 7 7 Non-locking push type Non-locking push type A (projecting) Nil Semi-standard For other rated voltages, please
However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC regarding IDFA100F to 150F. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted , the amount of processed air of 400 VAC can be found.)
25 20 30 22 22 18 10 0 0 0 27 27 32 38 20 20 30 32 2 2 14<12> 14<12> 58 58 218 218 80 40 37 32 50 25 40 3 20<17> 71 13 89 M10 x 1.5 depth 22 10 22 M22 x 1.5 80 3/8 10 122 10 20 264 100 40 37 41 60 30 50 3 20<17> 71 16 110 M12 x 1.75 depth 22 10 26 M26 x 1.5 100 1/2 10 122 10 20 264 50 35 32 63 35 32 11 11 58 72 10 10 23 20 M18 x 1.5 M18 x 1.5 55 69 1/4 1/4 10 10 102 102 7 7 18 18 M8 x 1.25
Note 2) Voltage symbol 23 (230 VAC) and 46 (460 VAC) are the terminal block connection as standard. The option S cannot be chosen. Voltage symbol 11 (115 VAC) is the power cable with plug as standard.
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other 1 2 3 4 5 6 7 9 Coil rated voltage 1 2 3 4 5 6 7 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Electrical entry G C TNote) D DL Option Electrical entry/With indicator light/ surge voltage suppressor Grommet Conduit Conduit terminal DIN terminal DIN terminal with
50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other
CQM CVQM C B Tap mounting A Through-hole mounting (mm) C B A Bore size 32 9.5 59 49.5 40 10 57 67 12 71 83 50 13 97 84 63 Features 1 Compact Cylinder with Solenoid Valve/ Guide Rod Type 32, 40, 50, 63 Series CVQM How to Order CVQM 32 30 M9BW 5 M Port thread type 32 40 Bore size 32 40 50 63 M5 x 0.8 Nil 32 mm 40 mm 50 mm 63 mm Rc G NPT 50 63 F N Piping Nil P Standard Axial Cylinder stroke
fluid flow rate: Rated flow rate (4) Power supply: 400 VAC(50Hz)/460 VAC(60Hz) 5: (1) Ambient temperature: 32 oC, (2) Circulating fluid: Clean water, (3) Circulating fluid temperature: 20 oC, (4) Load: Refer to the cooling capacity shown in the specification table, (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC(50Hz)/460 VAC(60Hz) (7) Piping length: Minimum 6
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.