MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)

Speed controller Cylinder Solenoid valve Tube Silencer Maximum return speed mm/s 100 200 300 6 ASD230FG CJ2 VJ500 TU0604 1m AN11001 10 16 Cylinder size 20 ASD330FG CM2 VZ500 TU0604 1m AN11001 25 Cylinder size 32 Values for pressure of 0.5MPa and temperature of 20C.

Note2) The value at temperature of 20C and O.D. variable rate 10% max.

53 External hold: 79 Internal hold: 90 MHKL2-16D 16 14 14.6 28.6 164 Double acting MRHQ MHKL2-20D 20 18 16 34 312 Auto switch MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 105 20 9 11 12 9 Normally open Normally closed MHKL2-16S 165 28.6 14.6 14 16 17 MHKL2-20S 314 34 16 18 20 32 MHKL2-25S 565 41 19 22 25 53 L1 Single acting MHKL2-12C 105 20 9 11 12 11 L2 MHKL2-16C 166 28.6 14.6 14 16 22 MHKL2-20C

16" 3/8" 3/16", 1/4" l/min (ANR) (CFM) 7 (0.25) 12 (0.42) 38 (1.33) Flow rate Controlled flow 0.1 (0.006) 0.6 (0.03) 0.2 (0.01) Effective area mm (cv) Free flow l/min (ANR) (CFM) Flow rate 175 (6.1) 350 (12.3) 75 (2.6) 295 (10.3) 5.3 (5.3) 2.7 (0.15) 1.1 (0.06) Effective area mm (cv) 4.5 (0.25) Note 1) Flow rates are the values measured with pressure at 0.5MPa (72psi) and temperature at 20C

46) I.D.holding :12.6 (56) MHK2-20D 20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S 25 13.0 (58) 14 19 33 15.6 Single acting L2 MHK2-12C 12 2.7 (12) 4 9 13 2.7 MHK2-16C 16 5.6 (25) 6 14.6 20.6 4.1 MHK2-20C

3/16" 1/4" 3/16", 1/4" 5/16" Tube O.D. 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 38 Flow rate l/min (ANR) Controlled flow 0.2 0.1 0.6 Effective area mm Flow direction symbols on body 230 180 100 460 260 390 Flow rate l/min (ANR) Meter-out type Meter-in type Free flow 3.5 2.7 1.5 7 4 6 Effective area mm Note) The flow rate value is at a pressure of 0.5MPa and temperature of 20C

Inch sizes 1/4", 5/16" 3/16" 5/32" 3/16", 1/4" 1/8", 5/32", 3/16", 1/4" l/min (ANR) {Nl/min} Flow rate 12 38 7 Controlled flow Effective area mm 0.2 0.6 0.1 l/min (ANR) {Nl/min} Flow rate 460 100 290 130 230 Free flow Effective area mm 7 1.5 4.5 2 3.5 Note) Flow rates are values measured with pressure at 0.5MPa and temperature at 20C.

Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.

Flow classification 11 The relation of the average free path of gas molecules and the pipe diameter D expressed as /D is the Knudsen number, and the relation of the pressure p(Torr) converted to air at 20C is expressed as pD.

Color Metric sizes (mm) Inch sizes (inch) 1 8 " 3 16 " 1 4 " 3 8 " 1 2 ( ) 5 32 4 ( ) 5 16 8 6 10 12 16 " (3.2) One-touch In/Out connection With quick disconnect and air lock Black General tubing 1.5MPa max. at 20C Nylon Tubing Series T White Red Blue Yellow Green Black White Slightly flexible 1.0MPa max. at 20C Red Blue Yellow Green Soft Nylon Tubing Series TS Black White Flexible 0.8MPa

Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).

Characteristic Cable length (L) Multicore vinyl cable 0.3mm2 X 25C Conductor resistance /km, 20C Voltage limit V, 1min, AC 65 or less 1.5m 3m 5m AXT100-DS25-015 Cable 25 core X 24AWG AXT100-DS25-030 10 1000 AXT100-DS25-050 Insulation resistance M/km, 20C 5 or more For other commercial connectors, use a 25-pin female connector made in conformity with MIL-C-24308.

Flow classification 11 The relation of the average free path of gas molecules and the pipe diameter D expressed as /D is the Knudsen number, and the relation of the pressure p(Torr) converted to air at 20C is expressed as pD.

This product is obsolete. Please contact us for the latest version.sales@ocaire.com

Series: 1 (VQZ1000), Stations: 4 Stations, Option: D0 (DIN Rail Mount w/o DIN Rail), Thread: 00T, Q: Q (CE Marked)

(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 460 920 790 1580 100 180 230 390 Flow rate (l/min (ANR)) Controlled (free) flow 7 14 12 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.

(at 20C) Data 10-12-9 9 Series CEP1 Proper Auto Switch Mounting Position Weight (Without mounting bracket/connector) (kg) Regarding dimensions for the proper auto switch mounting position (at stroke end), refer to page 1012-16.

Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.