Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .20787 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .36532 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .32524 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .25527 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .14431 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .21801 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, F29, 10 lb
10ms 5ms Maximum inrush current 0.7A 1.5A 0.7A 1.5A 7A 0.7A 1.5A 7A Maximum power 3W 4W 3W 8W 6W consumption ANALOGUE INPUT CHARACTERISTICS AC INPUT CHARACTERISTICS 10 6 inputs from I01 to I06 Input voltage 100-240 VAC + 10% 15%, 20 8 inputs from I01 to I08 50-60 Hz Measurement range 0-255 Input impedance >or = 800 kOhms Resolution 8 bits 10 000/256mV Pull-in votage at logic state 1 80V
OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 8 Series PSE Operation : Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5ms 20ms 160ms 640ms SET Press SET button.
Primary pressure normal Primary pressure drop Primary pressure increase P1 Set value P2 Time ON Switch output 1, 2 OFF Time [ ] Switch output response time 5ms or more 10ms or less when auto shift is input. Hi Auto shift input Lo 3 types of piping Different piping methods are possible to accommodate the installation location.
Aluminum, High Vacuum Angle Valve, HIGH VACUUM VALVE, L47, 1.44000 lb
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: None, Port Size: M5 (Body Ported M5X0.8), Thread: M Thread, Rc, Option: None, CE Compliant: Q (CE Compliant)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: Individual EXH, Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: M5 (Body Ported M5X0.8), Thread: Rc, Bracket: None, CE-Compliant: Q (CE-Compliant)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Pipe Port Type: M, Port Size: M5, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool, Pilot
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool, Pilot
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
XLD HIGH VACUUM VALVE. HIGH VACUUM VALVE, MAG/NO SW. VACUUM SERIES. XLD NO SIZE RATING. 3.47946 lb. 2X.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HIGH VACUUM VALVE, VACUUM SERIES, XLD HIGH VACUUM VALVE, 2X, XLD NO SIZE RATING, 3.40490 lb