Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature: Â
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: NRZ (N + R + Z)
Size: 40 (1/2), Port Size: 04 (1/2, Size 40), Accessories: B (Mounting Bracket), Bowl: 8 (Metal Bowl w/Sight Glass), Flow Direction: R (Flow Direction - Right to Left)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Size: 4 (40), Valve Type: 1 (Normally Closed), Body Material: S (Stainless Steel), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: R (Rc), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 1 (Front Exhaust), Thread: Rc, Port Size: 04 (1/2), Option: BG (w/Bracket + Round Type Pressure Gauge), Semi-standard: R (Flow Direction: Right to Left)
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 1 (Front Exhaust), Thread: Rc, Port Size: 04 (1/2), Option: None, Semi-standard: R (Flow Direction: Right to Left)
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 1 (Front Exhaust), Thread: Rc, Port Size: 04 (1/2), Option: B (w/Bracket), Semi-standard: R (Flow Direction: Right to Left)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket)
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: D [Float Type Auto Drain (N.O.)], Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Series: 742 (VP700), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC, 50/60Hz), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: R (w/Bracket
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: Standard, Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)
Series: 25A-PFMB7, Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Out Specification: F (Out 1: PNP, Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber), Unit Specifications: M (SI Unit Only), Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate)