SMC Corporation of America
Elite Part Number Search
Search Results "VVXA211-03-1"

Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Port Size: N01 (1/8 NPT), Applicable Tube OD: 03 (5/32"), Sealant: S (Sealant)

Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Port Size: N02 (1/4 NPT), Applicable Tube OD: 03 (5/32"), Sealant: S (Sealant)

Body Size: 2 (1/8, 1/4 Basis), Style: 3 (Universal), Control Method: 0 (Meter-out), Port Size: N01 (1/8 NPT), Applicable Tube OD: 03 (5/32"), Sealant: S (Sealant)

Set Flow: 10 (1~10l/min), Thread: Rc(PT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 1 [Neon Lamp (for 110VAC Red)]

Set Flow: 10 (1~10l/min), Thread: N (NPT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 1 [Neon Lamp (for 110VAC Red)]

Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: Â

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)

Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow:

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out, Gray Handle), Port Size: U02 (Uni 1/4), Applicable Tube O.D.: 03 (ø5/32")

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out, Gray Handle), Port Size: U01 (Uni 1/8), Applicable Tube O.D.: 03 (ø5/32")

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 03 (3/8)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 03 (3/8)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, FLOW CONTROL, SVD, 215 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, GB, AS 3/4INCH STANDARD (PT), .02846 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, FLOW CONTROL, 127.00000 lb

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, FLOW CONTROL, 19 lb