SMC Corporation of America
Elite Part Number Search
Search Results "C96SDC40-250C"

Magnet: D (Built-in Magnet), Mounting: B (Basic), Bore Size: 50mm, Stroke: 250mm, Cushion: C (Air Cushion and Rubber Bumper), Rod Boot: w/o Rod Boot, Rod: Single Rod, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal

Series: LEY, Size: 25, Motor Mounting Position: Top Side Parallel, Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 40: 8mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End, Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length: R5 (5m), Controller

Size: 25, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C61 [Parallel Input (PNP)], Mounting: 8 (DIN Rail)

Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 250mm, Cushion: C (Air Cushion), Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 20mm, Stroke: 250mm, Cushion: C (Air Cushion), Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: Built-in, Series: Standard, Head Cover Type: Basic Integrated Clevis, Bore Size: 25mm, Stroke: 250mm, Cushion: Air Cushion, Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Band, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -, Piston Rod Variation: -

Magnet: Built-in, Series: Standard, Head Cover Type: Basic Integrated Clevis, Bore Size: 20mm, Stroke: 250mm, Cushion: Air Cushion, Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Band, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Piston Rod Variation

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Series C96 cylinders conform to ISO 15552. The series is available with a single or double rod in 6 bore sizes from °32 to °125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25

Series C96 cylinders conform to ISO 15552. The series is available with a single or double rod in 6 bore sizes from °32 to °125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25

Series C96 cylinders conform to ISO 15552. The series is available with a single or double rod in 6 bore sizes from °32 to °125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25