26 32 38 41 13 17 22 24 Accessory Brackets (Optional) I-type single knuckle joint Bracket L tap 4-J counter bore 20: I-02 25: I-03 Material: Rolled steel 32: I-04 40: IA-04 Material: Cast iron 4-K Material: Cast iron RR1 I A B E F G NDH10 D +0.2 +0.1 MM 45 RR1 MM NDH10 M C E1 R U E1 U1 U1 A1 NX 8.6 A1 H L1 L1 NX Part no.

Basic inertia moment 2 r m I m : Weight of load (kg) r : Load center of gravity and distance of rotation axis. (m) r m Fig. (10) Inertia moment This shows inertia moment of m (weight) at r from the rotation axis. Calculation of inertia moment depends on the shape of the object.

Ek: Kinetic energy (J) M : Weight of attached object (kg) m : Weight of cylinders moving parts (kg) v: Maximum speed (m/s) va : Average speed (m/s) m M E a v 4 . 1 v k v 2 2 Note1) This is a mechanism which uses the compression of air to absorb the large kinetic energy generated by a large load and high speed operation when stopping the piston at the end of a stroke.

(Rated voltage 125 V, Plug JIS C 8303, Inlet IEC 60320-C13) *1 Measured with a high pressure probe of 1000 M and 5 pF *2 Measurement value based on a charged plate (Dimensions: 150 mm x 150 mm, Capacitance: 20 pF) as defined in the U.S.

Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m. (At 15 m: Reduced by up to 20%) 12. When checking the conductivity of the cable, be careful not to deform the connectors mating hole and terminals.

Conductor area: 0.2 mm2 Insulator O.D.: 1.12 mm Sensor cable PSE56--28: Oil proof heavy-duty vinyl cable with air tube 2 cores, 5.1, 3 m Conductor area: 0.2 mm2 Insulator O.D.: 1.12 mm Mass With sensor cable 200 g 108 g 194 g 102 g 201 g 109 g Without sensor cable 187 g 95 g 203 g 111 g 193 g 101 g -12No.PS-OMG0006-D Analogue output Range Rated pressure range A B C For vacuum 0 to -101 kPa

Rated pressure range A B ZSE3 0 to -101 kPa 0 -101 kPa ISE3L 0 to 98 kPa 0 98 kPa ISE3 0 to 0.98 MPa 0 0.98 MPa -25No.PS-OMO0002-A Dimensions Grommet type Z/ISE3-01/T1-26No.PS-OMO0002-A Connector type Z/ISE3-01/T1-C -27No.PS-OMO0002-A Single-installation type Grommet type ZSE3-0X-28No.PS-OMO0002-A ZSE3-0X--D -29No.PS-OMO0002-A Connector type ZSE3-0X-C -30No.PS-OMO0002-A ZSE3-0X-C-D -31No.PS-OMO0002

type snap ring Aluminium alloy Clear anodized Stainless steel 9 19 Cap B Parallel pin Aluminium alloy Clear anodized NBR 10 20 Cap C Piston seal Urethane rubber NBR 11 21 Head damper Gasket Stainless steel Nit riding NBR 12 22 Rack Gasket Bolts for body through hole mounting Replaceable parts list Description Kit No.

CKQ CLKQ Relay, PLC Note 1) D-P4DWZ 5 m 2-wire (14) 2-color display CK1 D-P79WSE 24 VDC 0.3 m Pre-wired connector DC/AC magnetic field Reed auto switch CLK2 Series C(L)KQP D-P74L 3 m 24 VDC 100 VAC 1-color display 2-wire Grommet D-P74Z 5 m Note 1) PLC: Programmable Logic Controller Note 2) There are other applicable auto switches other than the listed above.

Part number Description Remarks ZS-28-A Power and output lead wire and connector Length: 2 m ZS-28-B Bracket Mounting screw (M3 x 5 L) 2 pcs. ZS-28-C-1 Sensor connector 1 pc. ZS-27-C Panel mount adapter Mounting screw (M3 x 8 L) 2 pcs. ZS-27-D Panel mount adapter + Front protective cover Mounting screw (M3 x 8 L) 2 pcs.

Part number Description Note ZS-33-D Lead wire with connector Length: 2 m ZS-33-F Connector cover Silicone rubber ZS-42-C Bracket With mounting screws for PFMB7501/7102 (4 pcs. with nominal diameter of 3.0) ZS-42-D Bracket With mounting screws for PFMB7202 (4 pcs. with nominal diameter of 3.0) -10No.PF-OMP0002-H Summary of Product parts Body Name Description Display 1 See below.

Lead wire length (m) Load voltage Auto switch part no.

SPEEDCON connector wiring method is explained below. (1)Align the mark B on the metal bracket of the cable side connector (plug/socket) with the mark A. (2)Align the mark C on the unit and insert the connector into the unit vertically.

Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide

1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721 30 250 -79No.PF-OMM0004-D / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -80No.PF-OMM0004-D PF3W704/720/740/711 A AA B D E F G H J K L N P PF3W704 3/8 70 50 30 60 40.6 15.2 24 14

Exterior dimensions Grommet: G Face seal fitting / compression fitting Terminal part Flat terminal connector 250 Series Model A B Bs C D E F L M P [inch] Grommet: G Grommet: GS Conduit: C Fast on: F DIN terminal: D Terminal: T G H G H G H G H G H J G H J XSA1-2S 22 55 24 63 30 8.5 20 3 8 27 53.5 30 40 47.5 47.5 23 53.5 64.5 45.5 52.5 99.5 47.5 68.5 -2V 50 1/4 XSA2-2S 63 31.5 73.5 63 32.5

B H C D d NT-02 NT-03 NT-04 M8 X 1.25 13 5 15.0 12.5 CJP M10 X 1.25 17 6 19.6 16.5 M14 X 1.5 22 8 25.4 21.0 CJ2 Mounting Nut (mm) CM2 Material: Carbon steel C85 Applicable pin part No. Part No.

Speed exhaust controller Option None P The effective area is two times larger With spatter cover C Body size than that of speed controller. Hexagonal lock nut K M3 M5 1/8 1/4 3/8 1 2 3 4 5 Note) Option should be indicated in order of C and K. Only available for ASV310F,410F and 510F.