Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 06 (3/4), Option: Standard, Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Magnet: D (Built-in), Mounting: B (Basic Style), Style: N (Non-lube Rubber Bumper), Bore Size: 25mm, Thread: TN (NPT Ports; M5 for Air Cushion 20 & 25 Bore), Seal Material: V (FKM), Stroke: 125mm
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: M (Round Type Pressure Gauge w/Color Zone), Attachment: SV (S + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Magnet: D (Built-in Magnet), Mounting: D (Clevis), Type: A (Air Cushion), Bore: 25mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: V (Single Knuckle Joint)
M5 female); 1/8 Rc (female); 1/4 URJ; 1/4 TSJ
M5 female); 1/4 URJ; 14 TSJ
M5 female)
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available
Pressure sensing for air and liquid non-corrosive to 630 and 304 SST; Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc with M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, Kpa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port size: M5 female; Panel mounting adapter available
Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch output (NPN or PNP), plus 1 analog output (V or mA); Port size: M5 female; Panel mounting adapter available
Great value for pressure sensing in dry environments; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket or panel mounting options
Great value for vacuum sensing in wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket or panel mounting options
Great value for vacuum sensing in wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket or panel mounting options
Vacuum sensing for air and liquid non-corrosive to 630 and 304 SST; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female); 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Vacuum sensing for air and liquid non-corrosive to 630 and 304 SST; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female); 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Pressure sensing for air and liquid non-corrosive to 630 and 304 SST, up to 2 MPa; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female): 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Great value for vacuum sensing in wet or dusty environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket mounting options
Great value for vacuum sensing in wet or dusty environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket mounting options