Moment Nm Load N Load N Load N Piston speed m/s Piston speed m/s Moment Nm Piston speed m/s Piston speed m/s Moment Nm Piston speed m/s Piston speed m/s Allowable kinetic energy horizontal Mounting Vertical Mounting Load N Load N Piston speed m/s Piston speed m/s 19 5-4 Example of selection .
Option [Actuator cable] LE CP 1 B S Cable type Cable length Nil S Robotic cable Standard cable 1.5 m 3 m 5 m 8 m 10 m 15 m 20 m 1 3 5 8 A B C Motor option Nil B Without lock With lock Produced upon receipt of order (Robotic cable only) [I/O cable] Pin no.
= meter mils = 0.001 inch in = inch ft = foot @ = cubic centimeter L = liter gal (U.S.) = U.S. gallon g = gram kg = kilogram Oz = OunCe lb = pound gf=gram-lorce kgf=kilogram-force N = neMon lbf=pound-force N . m = n e M o n m e t e r kg.m=kilogram-meter ft. lb = foot pound mm (H2O) = millimeter water column in (H2O) = inches water column mm (Hg) = fnillimeter mercury column in (Hg) = inches
1, @2 and @6 each. 12 GR-S-020(20g) MXY12-PS GR-S-050(50g) 223 Series MXY Dimensions 2 x M5 x 0.8 Piping port J + Stroke Same in case of the type of centralized piping on one side without switch rail ( ) JH Piping port (Plug: M 5P) 2 x M5 x 0.8 Piping port FL (Plug: M-5P) 2 x M5 x 0.8 21 21 FH 2 x M thread depth MM +0.03 0 R RL Width across flats MB (lock plate fixing bolt) PR MA (Stroke
= meter mils = 0.001 inch in = inch ft = foot @ = cubic centimeter L = liter gal (U.S.) = U.S. gallon g = gram kg = kilogram Oz = OunCe lb = pound gf=gram-lorce kgf=kilogram-force N = neMon lbf=pound-force N . m = n e M o n m e t e r kg.m=kilogram-meter ft. lb = foot pound mm (H2O) = millimeter water column in (H2O) = inches water column mm (Hg) = fnillimeter mercury column in (Hg) = inches
2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !
300mm (lead wire length) I With indicator light/ surge voltage suppressor G G Manual override (locking lever type) Pressure gauge mounting bore 1/8 Port size Indicator light ON OFF OFF ON B B H H N P A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN SMC SMC Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000
HRS Series 6.1 Option J [Automatic fluid filling] 6-1 HRX-OM-R016 Chapter 6 OptionOptional Accessories 6.2 Option M [DI water (Pure water) piping] 6.2.1 Option M [DI water (Pure water) piping] This option is for customers who use DI water (pure water) as circulating fluid.
They should be used only to provide support. m m -36 Guide for intermediate support LEMB Guide for intermediate support LEMC 25 25 LEMC32 20 20 Workload m[kg] Workload m[kg] 15 15 LEMB32 LEMC25 10 10 LEMB25 5 5 0 0 0 200 400 600 800 1000 1200 1400 0 200 400 600 800 1000 1200 1400 Support spacing [mm] Support spacing [mm] Guide for intermediate support LEMHT Guide for intermediate support
2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !
6 @4 @5 @2 @1 r #0 #4 #2 o !5 @8 @3 REBHT32 @6 Parts list Parts list No. Description Material Note No.
NCmRO-OT NCI|RO-OS H3 ).250 | r-24 o.75 |.0010.621 r2s6;; 093t0.22 t0-32 uNFl0.8l L00 1 . 1 20.12 t10-32 UNF $-m 0.62 0.34 0.880.38 3.22 2.66 2.35 1.69 t.312tyt -24 003t025 O-32UNF .12 r25 1.47 0.2,1 llG32 UtlF 1A-20 0.s10.47 1.22 o.62 3.75 3.34 2-93 1.81 ).137 t%^-20 r.25 1.m).12510-38 | r. -20 UNC 't.75 1.93 0.25 t|l-20 LhrC x.-18 1 . 1 20.38 1.57 0.88 4 . 1 9 3.49 3,692.O0 slrc' Air Cvlinder
HRS Series 6.1 Option J [Automatic fluid filling] 6-1 HRX-OM-R005 Chapter 6 OptionOptional Accessories 6.2 Option M [DI water (Pure water) piping] 6.2.1 Option M [DI water (Pure water) piping] This option is for customers who use DI water (pure water) as circulating fluid.
Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Basic inertia moment 2 r m I = m : Weight of load (kg) r : Load center of gravity and distance of rotation axis. (m) r m Fig.9 Inertia moment This shows inertia moment of m (weight) at r from the rotation axis. Calculation of inertia moment depends on the shape of the object.
"M" in the part number means that the unit cannot be changed.
to 149 m 498 Vertical Suction Filter FHIA Series How to Order FH I A N 04 M M R 074 Vertical suction filter Relief valve Hydraulic fluid R D N W V With relief valve None (Blanking plate) Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication Port size M E D Differential pressure indicator Differential pressure indication switch Note) 04 06 08 10 12 16 20 24 28
"M" in the part number means that the units cannot be changed.
pressure ZSE50 02 M F L 22 For compound pressure Piping specifications Option 02 T2 G2 R 1/4 (M5 with female screw), Piping in backward direction Nil None NPT 1/4 (M5 with female screw), Piping in backward direction Bracket A G 1/4 (M5 with female screw), Piping in backward direction Optional A Input/output specifications 22 30 62 NPN open collector 2 output + Analog output Bracket D NPN