Function: 4 (3 Position Exhaust Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: D (N.O. Float Type Auto Drain), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Base Mounted Wiring: 01FU (Plug-in w/D-Sub Connector on U Side), Stations: 06 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: T (NPTF)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 09 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 06 (3/4), Thread: T (NPTF)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: DG (D + G), Attachment: TV1 (T + V1), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 03 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 06 (3/4), Thread: T (NPTF)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: D [Float Type Auto Drain (N.O.)], Attachment: STV (S + T + V), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: RZ (R + Z)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Style: Pressure Switch w/ T-Spacer, Body Size: 60 (AC50, AC60), Thread Type: N (NPT), Port Size: 06 (3/4), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: P (MPa/psi Dual Scale)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: Standard, Attachment: TV1 (T + V1), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port: 06 (3/4), Option: D [Float Type Auto Drain (N.O.)], Attachment: TV (T + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: DG (D + G), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)