1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Terminal 1/2, Non Plug-in Standard 1/2)
Terminal 1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in Standard 1/2)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, F7, AS 1/2INCH EUROPEAN, .53541 lb
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: Â
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °C)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FSC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant), Push lock: A (Push-lock)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, HIGH TEMP, AIRLINE EQUIPMENT, AS FLOW CONTROL, DB, AS 1/4INCH STANDARD (PT), .30119 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)
Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: N (NPT), Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: G (Round Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl Type + Lubricator: 2 (Metal Bowl), Bowl Guard: None, Air Filter Drain
Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: N (NPT), Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl Type + Lubricator: 2 (Metal Bowl), Bowl Guard: None, Air Filter Drain Port: J (Drain Guide 1/8: Body
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: G (G), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: without Sealant, Push lock: A (Push-lock)