Series VX21/22/23, is a direct operated 2 port solenoid valve for air, gas, vacuum, water, steam and oil. Proper selection of body and sealing materials permits application of a wide variety of fluids. Application can be matched by simply choosing body materials (brass, stainless steel), seal materials (NBR, EPR, FPM, PTFE) and the solenoid coil (class B, class H).
Series VX21/22/23, is a direct operated 2 port solenoid valve for air, gas, vacuum, water, steam and oil. Proper selection of body and sealing materials permits application of a wide variety of fluids. Application can be matched by simply choosing body materials (brass, stainless steel), seal materials (NBR, EPR, FPM, PTFE) and the solenoid coil (class B, class H).
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
32 25 20 5.5 5.5 5 200 to 1000 150 to 1000 150 to 700 150 to 700 10 8 8 8 26.5 22 20 20 12.5 11 10 10 24 22 22 18 46.5 37.5 33.5 22 17 17 13 21 19.5 19.5 15.5 55.5 49.5 45.5 40 7 6.8 6.8 6.8 30 28 28 25 227 199 186 186 55 40 40 40 75 55 55 55 51 42.5 34.5 14 12 10 M10 x 1.25 M14 x 1.5 7 56.2 Bore size Y X NN 264 232 219 215 P 181 159 146 146 S 10 8 8 8 Z ZZ Stroke range 1/8 1/8 1/8 1/4 23
blanking plate assembly VK3000-7-1A G NPT R1 port: M5 x 0.8 R2 port: M5 x 0.8 P port: Rc 1/8 20 20 stations NPTF 3-2-3 Series VK3000 Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Combination of Blanking Plate Assembly and Manifold Base 5 port body ported: VK3120 5 port base mounted: VK3140 Blanking plate assembly: VK3000-7-1A M3 x 26 Round head combination screw DXT199-23
19 380 369 20 399 388 L1 L2 VV061 VV100 V100 S070 VQD VQD-V VK VK VT 1415 A VK300 Series Type 40 Manifold/Base Mounted (Bottom ported) VV3K3-40Stations -01 Grommet: G DIN terminal: D Applicable cable O.D: 3.5 to 7 Max.10 69.8 83.4 75.9 2 x 4.5 (Mounting hole) Manual override (Non-locking) Pg7 300 (Lead wire length) 4 x Rc 1/8 (P, R port) 4 x Rc 1/8 (P, R port) 2 x 4.5 (Mounting hole) 39 23
7 2 x M2.5 x 0.45 (Mounting screw) (Mounting screw) V100 Pg7 S070 Mounting screw ( ) 4 3 VQD 2 x 3.5 57.9 Mounting hole ( ) 63.4 50.4 VQD-V (Bleathing hole) 24 21 VK VK 2.3 68.1 VT 3R2 5R1 1P Refer to grommet type for other dimensions. 2 x M5 x 0.8 (R1, R2 port) 1423 VK3000 Series Dimensions: Base Mounted Grommet: VK3140-G-01 DIN terminal: VK3140-D-01 2 x 4.3 (Mounting hole) 32 4 B A 26 23
Hz), 17 VA (60 Hz) 12 W Allowable voltage fluctuation DC AC Inrush Holding Apparent power Note) Power consumption Note) DC Semi-standard Note) At rated voltage Flow Rate Characteristics/Weight Weight (kg) 1 2 (IN OUT) 2 3 (OUT EXH) Flow rate characteristics Port size Valve model Grommet C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(IN), 2(OUT) 3(EXH) 3 8 1 2 3 4 19 0.43 5.5 18 0.47 5.4 23
Indicator 45 22.5 27 1/8 Pilot port 5 17 D E OUT IN E C B 2 x P Port size A A Dimensions [mm] Model Port size P A B C D E VXB215A D 3/8 23 55 99.8 88.3 11.5 VXB215B E 1/2 27 65 106.8 90.8 13.5 VXB215C F 3/4 32 75 111.5 93.2 16 6 VXB Series For Steam Replacement Parts How to order the maintenance kit Maintenance Kit Insulated Adapter (for Individual Parts) VXB021-20-1A (1 set) VXB215 KT *
W-R3 Series Dimensions W-R1-S2Position of fulcrum 2 x 18.5 Proximity switch mounting bracket 68 Proximity switch (Option) 117 15 15 26 26 2 x Rc3/8 36.5 6.5 R5 30 50 190 117 250 220 200 140 30 60 2 x M8 x 1.25 thread depth 13 (External cover mounting screw) 11.5 4 x 13 through 4 x 11 4 x 20 counterbore depth 8 (Mounting hole) 18 (Clamp block mounting hole) 500.03 2 x 8H7 +0.015 0 14 117 45 23
D-X 12.5 20Data Symbol S Z Stroke Bore size (mm) 4 5 10 15 20 5 15 20 10 18 23 28 33 51 61 66 56 6-2-3 4 Air Cylinder Single Acting, Single Rod, Spring Return Series CJ1 2.5, 4 How to Order/Single Acting CJ1B S 4 10 U4 Applicable tubing Mounting style Basic style Size O.D. 4 mm 4 mm B Tubing material Symbol Bore size 2.5 mm 2.5 mm Bore size Polyurethane Soft nylon Courtesy of Steven Engineering
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: TV (T + V), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 01 (1/8), Option: C [Float Type Auto Drain (N.C.)], Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Pressure range: 15 to 145 PSI (0.1 to 1 MPa) , Ambient and fluid temp range: 23 to 140and#176;F (-5 to 60and#176;C) , Option for meter-out or meter-in type control, One-touch fitting provides easy tube mounting/removal, Applicable tube size: °4, °6, °8, °10, and °12, Thread port size: M5, R1/8 to 1/2 , The port thread has sealant (except M5 type), to save installation time and reduce the
Model: 23, Orifice Diameter: 6 (10 mm), Valve/Body Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: L (SUS Body, FKM, Class B, High Corrosive, Oil-Free), Suffix: Standard, Port Size: 03 (3/8), Thread Type: N (NPT), Voltage: 5 (24VDC), Lead Wire: G (Grommet)
SMC's series VXK21/22/23, 2-port solenoid valve was designed with a Y type strainer installed inside the body to remove foreign materials mixed in fluids before they enter the actuating part of the valve (armature), as well as preventing the flow of foreign materials to downstream equipment.