SMC Corporation of America
Elite Part Number Search
Search Results "VV3P5-42-103-03T"

direction through-hole type 4-3.4 (Hole for mounting attachment) 8 0.005 0.025 4 7 14 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-12 12 180 Angular Style Air Gripper Cam Style Series MHY2 MHY2-20D 2-M5 x 0.8 thread depth 8 (Mounting hole) Pin hole positioning 14 5 19 MHZ 42

26H9 Depth 1.5 +0.052 0 Postioning pin hole 30 60 18 86 30 107 Auto switch mounting groove position M5 X 0.8 (Finger operating port) O 24 14 S 3 M5 X 0.8 42 8 4 (Finger closing port) 3 MHY2-25D2 Opening/closing direction through hole type 4-5.5 (Hole for mounting attachment) 12 0.005 0.025 6 12 22.5 (Limted area for mounting attachment) Do not extend the attachment from limited area for

DIN terminal (D) Electrical entry For manifold use, refer to the pages 4-6-8 to 4-611. 100, 200, 24, 48, 110, 220 AC50/60 Hz DC Coil rated voltage (V) 24, 6, 12, 48 15 to +10% of rated voltage Allowable voltage fluctuation (%) 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Power consumption (W) Note) [Current mA] DC Inrush 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42

(For type 20, 41, 42 and 45) Pilot pressure range SS5YA Fill the same as SS5Y . 3 5 7 3 5 7 Pilot pressure MPa Specify the part numbers for valves and options together beneath the manifold base part number. (Example) SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.) SYA5140 1 set (Single air operated valve part no.) SYA5240 1 set (Double air operated valve part no.)

Single solenoid SZ3160-5MO Common connector assemblies SX100-42-4D Port B Port A Plug position N.C. N.O.

Unit for replacement Combination of supply valve and release valve S 0.3 to 0.7 mm B 0.5 to 1.2 mm Piping specifications Unit for replacement (Refer to page 13-2-42 for details.)

)/ 0.7 W 10 VDC (Rated 42%)/ 0.7 W 5 VDC (Rated 42%)/ 0.7 W 10 VDC (Rated 42%)/ 0.7 W 4.2 VDC (Rated 35%)/ 0.8 W Holding*2 Holding voltage/ Power consumption *1 For use with fluids other than air or nitrogen, please contact your SMC sales representative. *2 Please make sure the coil surface temperature does not exceed 80C.

ARJ 1.6 Bracket AR425 to 935 Mounting hole for hexagon panel nut 42 25 Bracket (Option) ARX 25 Max. 4 AMR Pressure gauge (Option) ARM 34 Panel 28 ARP 4.5 8.4 IR-A IR-A M10 x 1 31 25 IR 7.5 Mounting hole 1.6 M28 x 1.5 IRV 4.5 VEX 2 x 1/8 Port size 90.5 53.5 SRH 45.9 37.6 9.8 SRP OUT IN 30 SRF 2 x 1/8 Pressure gauge port 43.5 EXH EXH ITV 35 IC When connecting to the EXH port, contact your

CN1 (Note 3, 5) Emergency stop Servo-on Reset Proportion control External torque limit selection Forward rotation stroke end Reverse rotation stroke end EMG SON RES 42 15 19 17 18 43 44 47 (Note 7) CN6 PC 3 1 2 MO1 Analog monitor 1 (Note 12) TL LG LSP LSN MO2 Analog monitor 2 (Note 5) Plate SD DOCOM Upper limit setting P15R 1 2m max.

How to change the number of cups . 39 6.1 Change to 1 cup (with flange) . 39 6.2 Change to 1 cup (without flange) . 40 6.3 Change to 2 cups . 41 7.Maintenance . 42 7.1. Maintenance for vacuum gripper. 42 7.2. Maintenance for suction cup . 43 8.Precautions . 44 8.1 Air supply . 44 8.2 Vacuum gripper precautions . 44 8.3 Suction cup precautions . 46 9.Trouble shooting . 49 -1No.

(Refer to page 42) Output does not turn ON Air leakage Connect piping correctly and eliminate any air leakage. Setting is not correct Perform setting correctly. (Refer to page 42) Output stays ON (Does not turn OFF) Clogged piping Apply pressure lower than the withstand pressure to eliminate the cause of clogging of piping. Incorrect wiring Connect wires correctly.

A B C D E F G H I Model How to Order VHS20 VHS30 VHS40 VHS40-06 VHS50 59 78 107 110 134 20 29 39 42 53 40 53 70 75 90 34 46 63 67 78 22 21 26 45 55 58 65 76 33 42 44 50 61 28 30 36 44 54 45 55 63 69 81 30 03 RZ F VHS 3-port valve for residual pressure release Caution 1. Consult P/A when a pressure switch and T type spacer are installed on the outlet of pressure release valve 2.

L plug connector (L): SYJ54-L-01 M plug connector (M): SYJ54-M-01 DIN terminal (D): SYJ54-D-01 M8 connector (W0): SYJ54-W0-01 Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.4 74.9 MAX. 10 74.6 49.6 [56.6] 63.6 34.2 48.5 54.1 M8 x 1 36.6 Approx. 300 (Lead wire length) 60.7 [67.7] Pg7 6 6 6 6 65.5 [67.7] 55.7 [57.9] 75.5 64.6 57.2 50.7 42 42 42 42 34.7 17 9 17 9 17 9 17 9

(mm) Weight (g) M A L D Part No. 3.2 4 33.5 34.5 36.5 18.5 KAR23-04 18.5 17.5 18 15.5 9.6 3.4 2.9 2.3 2.1 5 KAR04-06 KAR04-08 5.6 5.6 6 8 10.4 4 16 12.8 10 KAR04-10 39.5 37 39.5 3.6 3 KAR06-08 8 18.5 6 10 KAR06-10 17 12.8 KAR06-12 42 5.2 12 20 3.5 13.1 13.1 8 KAR08-10 41 4.5 18.0 18.0 10 20 18.5 15.2 KAR08-12 42 5.1 12 10 KAR10-12 42 33 32.8 32.8 12 20 21 17 139

ARJ 1.6 Bracket AR425 to 935 Mounting hole for hexagon panel nut 42 25 Bracket (Option) ARX 25 Max. 4 AMR Pressure gauge (Option) ARM 34 Panel 28 ARP 4.5 8.4 IR-A IR-A M10 x 1 31 25 IR 7.5 Mounting hole 1.6 M28 x 1.5 IRV 4.5 VEX BLEED 90.5 2 x 1/8 Port size 53.5 SRH 45.9 37.6 9.8 SRP OUT IN 30 SRF 2 x 1/8 Pressure gauge port 43.5 EXH EXH ITV 35 IC When connecting to the EXH port, contact

17.5 42 62 M14 x 2 35 M12 x 1.75 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z Nil TN TF 80 (56 x 2) 10.6 17.5 10 Rc1/4 NPT1/4 G1/4 24.5 23 37 38 64 55 155 118 184 25.5 42 M12 x 1.75 18 9.5 100 (71 x 2) 12.5 20 12 Rc1/4 NPT1/4 G1/4 31.5 25 38 40 74 71 187 141.5 219 27.5 46 M14 x 2 21 11 9 JMGP Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke

mm) Rod end male threads Water resistant type (mm) a b c e f g h Bore size (mm) B C N S g h A Bore size (mm) 20 20 12.5 15 M10 x 1.25 6 10 23 66 61 43 18 26.5 6 33 76 25 25 15.5 18 M12 x 1.25 6 12 26 71 63 45 18 30 6 36 81 32 32 22 25 M16 x 1.5 7 14 35 86 71 51 20 38 7 45 96 40 40 27 30 M20 x 1.5 7 19 40 95 75 55 20 45 7 50 105 50 50 32 35 M24 x 1.5 8 24 46 106 81 60 21 55 7 56 116 63 63 42

Calculation: Example) CJ2YL10-45Z O Basic weight 22 (10) O Additional weight 4/15 stroke O Cylinder stroke 45 stroke O Mounting bracket weight 8 (Axial foot) 22 + 4/15 x 45 + 8 = 42 g Auto Switch Made to Order 3-1 A Series CJ2Y Dimensions Basic (B) CJ2YB Bore size Stroke Head cover port location Z NDh8 Section Y detail Mounting nut Rod end nut Piping port 2 x M5 x 0.8 Y GA NN GB C MM D

23.5 45 2 11-/22-MXP6-51 30 35 53 48.5 47 37 11 10 42 30 60 9.5 11-/22-MXP6-10 834 Air Slide Table MXP/MXPJ6 1122Dimensions: MXP10 11222 x M3 x 0.5 depth 5 Z 3 Metal stopper V K C 4 5 C Max. 5.5 20 G Without stroke adjuster N M Max. 3.5 C Stroke: S 2 x M3 x 0.5 depth 3 11-/22-MXP10-10 A Width across flats 1.5 H 13 (Plug: MGP12-08-CA001-R) 2 x M5 x 0.8 Piping port Width across flats 5.5 4

10 46 11.5 23 62 16 1 CY1S10-Z M8 x 1 RJ0806HN M4 x 0.7 M50.8 25 38 61 60 5.5 11 47 12.5 58 14 28 72 1 24 CY1S15-Z M8 x 1 RJ0806LN M4 x 0.7 M50.8 30 50 76 75 5.5 11 62 12.5 73 14 28 87 30 1 CY1S20-Z M10 x 1 RJ1007LN 40 70 90 90 4.5 9 73 16.5 87 18.5 37 106 M6 x 1 Rc1/8 NPT1/8 G1/8 38 1.5 CY1S25-Z M14 x 1.5 RJ1412LN 73 M6 x 1 Rc1/8 NPT1/8 G1/8 40 70 99 90 4.5 9 16.5 96 18.5 37 106 42