Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant), Push lock: A (Push-lock)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, C7, AS 1/8INCH EUROPEAN, .18568 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, D7, AS 1/4INCH EUROPEAN, .30388 lb
Atex: 55- (ATEX category 2 - II 2GDc), Body Size: 5 (1/2 Standard), Body Material: 1 (ADC12, Aluminium), Diaphragm Material: 1 [PTFE (Fluororesin)], Switching Type: 3 (Air Operated), Thread: F (G), Port Size: 04 [1/2 (15A)]
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Actuation Type: 4 (3 Position Exhaust Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 1 (100VAC 50/60HZ), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: N (NPT)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: BG (B + G), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: R (External Pilot), Voltage: 3 (110VAC 50/60HZ), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: N (NPT)