Refer to the section below for piping the HEP500-04 liquid collector.
Create a branch in the piping that supplies the cutting oil to the processing equipment, and then pipe it to the IN side of the liquid collector. Connect the liquid collector and strainer with an O.D. ø6 nylon tube. The tube should be provided by the customer.
Cylinder series Bore size (mm) 32 40 50 63 80 100 125 140 160 180 200 CDA1, CDBA1, CDV3 BT -04 BT -04 BT -06 BT -08 BT -08 CDVS, CDLA, CE2, CNA CDL1 BT -12 BT -12 BT -16 BT -18A BT -20 CDS1 MDB/MDBB BT03 BT03 BT05 BT05 BT06 BT06 Part No. of auto switch mounting bracket (including bracket and screw) Cylinder series Bore size (mm) BBA1: For D-A5/A6/F5/J5 D-F5BAL is mounted on the cylinder with
Adaptor connection thread Symbol Pad dia. 1 02 to 08 B5 2 10 to 16 3 20 to 32 B8 4 40, 50 T 2 ZP B5 [qAdaptor] R S ZP 04 A5 [wR type adaptor] Symbol S Pad dia. 02 to 16 L 20 to 50 With Buffer ZP R 16 K20 A10 06 UGN [Pad model no.]
(Example) SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.) SYA5140 1 set (Single air operated valve part no.) SYA5240 1 set (Double air operated valve part no.) SY5000-26-2A 1 set (Blanking plate assembly part no.) Operating pressure MPa The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
VZA
Example: SS3YJ3-20-03 .1 pc. (Manifold base) SYJ312-5LZ-M3 .2 pcs. (Valve) SYJ300-10-1A .1 pc. (Blank plate ass'y) SS3YJ3-42R-03-C4 .1 pc. (Manifold base) SYJ314R-5G .2 pcs. (Valve) SYJ300-10-2A .1 pc.
Series VQC4000 Base Mounted Plug-in Unit How to Order Manifold VQC F L M VV5QC 4 1 08 02 TD0 / / / SQ P T VQ0 Kit VQ4 S Kit VV5QC 4 1 16 03 SDQW VQ5 Series Option VQZ 4 VQC4000 Nil K N None Special wiring specifications (except for double wiring) Note 1) Manifold model VQD With name plate (available for T kit only) Note 2) 1 Plug-in unit When specifying more than one option, enter symbols
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2009 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing NT printing NT 12200SZ Printed in Japan.
Rod boot MB W R K F MB1 CP95 Stroke (mm) Refer to standard stroke table on p.1.11-4 C95 Applicable Auto Switches/ Tie rod mounting C92 Load voltage Lead wire (m) Indicator Mounting bracket Applicable load Auto switch model Special function Style Electrical entry Wiring (Output) 0.5 () 3 (L) 5 (Z) AC DC CA1 3 wire (Equiv. to NPN) 5V A56 IC CS1 Yes Reed switch Solid state switch 32,40 BT-03
C8 C10 C12 02 03 B CM With 8 One-touch fitting With 10 One-touch fitting With 12 One-touch fitting Rc 1/4 Rc 3/8 Bottom ported Rc 1/4 Mixed Note 1) Numbers inside ( ) indicate the maximum number of solenoids for mixed single and double wiring. The maximum number of stations is determined by the total number of solenoids. In the case of mixed wiring, use the option symbol "-K."
RUSSIA SMC Pneumatik LLC. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing April, 2003 D-DN P-120 (DN) Printed in Japan.
Thread type Note 2) Option Symbol Type Rc NPT G Symbol Nil Option Nil N F B N Port size Port size 3/8" None With foot With silencer Symbol 03 When multiple options are required, indicate them in alphabetical order. For AIR EXH: AN20-02 (: Either Nil or N is entered as a thread symbol.)
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Request to read Address BCC data End code Identification code Start code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address Start code BCC data Affirmation code End code Numerical data Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Address BCC data End code Request to read Start code Identification code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address BCC data End code Start code Numerical data Affirmation code Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing January, 2001 D-SMC.L.A.
Housing Port Size (1/16 of an inch) Shaft Port Size (1/16 of an inch) Housing Port Configuration: 01 = Male NPTF(Non-Standard)* 02 = Female NPTF 03 = Male JIC 37 Degree 05 = Male SAE O-Ring Straight Thread 06 = Female JIC 37 Degree 07 = Female NPSM Pipe Swivel 10 = Female SAE Straight Thread JM = Seal-Lok Shaft Port Configuration: 01 = Male NPTF 02 = Female NPTF 03 = Male JIC 37 Degree 05
Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.