Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 150 (1 1/2"), Stroke: 100 (1"), Body Option: M (Male Rod End)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Z (Super Compact), Bore Size: 200 (2"), Stroke: 100 (1"), Body Option: M (Male Rod End)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, AIR CUSHION, ACTUATOR, RQ COMPACT CYLINDER, PE, 63MM RQ DBL-ACT AUTO-SW, 3.12056 lb
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking)
Size: 100, Motor Mounting Position: D (In-line), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: D (3.33mm), Stroke: 100mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Driver Type: N2 (LECSN2-T9/without Network Card, 200V to 240V), I/O Cable Length: 1 (
Motor Type: S8 [AC Servo Motor, (Absolute Endcoder), 400W], Lead: 5mm, Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 2m, Driver Type: B2 [LECSB2/Pulse Input Type, (Absolute Encoder), 200V to 230V], I/O Connector
Motor Type: S8 [AC Servo Motor, (Absolute Endcoder), 400W], Lead: 10mm, Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 10m, Driver Type: LECSC2/CC-Link, (Absolute Encoder, I/O Connector: w/Connector
Size: 32, Motor Mounting Position: D (In-line), Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: H (Size 25: 20; Size 32: 24), Stroke: 100mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 5 (NPN)
Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options
Size: 25, Motor Mounting Position: Top Side Parallel, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: H (Size 25: 20; Size 32: 24), Stroke: 100mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)
Size: 25, Motor Mounting Position: Top Side Parallel, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 16: 10; Size 25: 12; Size 32: 16), Stroke: 100mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 100, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector),
Size: 100, Motor Mounting Position: D (In-line), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: D (3.33mm), Stroke: 100mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 2 (2m), Driver Type: B2 (LECSB2-T9/Pulse Input, 200V to 240V), I/O Cable Length: 1 (1.5m)
Size: 100, Motor Mounting Position: Top Side Parallel, Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: D (3.33mm), Stroke: 100mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Driver Type: P2 (LECSN2-T9-P/PROFINET, 200V to 240V)
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male Rod End