SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2D50-600-D-M9PSDPC"

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 600mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: None, Stroke: 600mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: None, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: TN, Stroke: 600mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Axial Foot, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: TN, Stroke: 600mm, Option: None, Lock Style: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: None, Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: TN (NPT), Stroke: 600mm, Bellows/Cushion: Cushion Both Sides

Magnet: D (Built-in), Mounting: D (Double Clevis), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: F (Rod Flange), Tube Material: F (Steel Tube), Bore Size: 100mm, Thread: TN (NPT), Stroke: 600mm, Bellows/Cushion: Cushion Both Sides

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Bore: 50mm, Port Thread: Rc, Piping: Flange Side, Stroke: 30mm, Action: D (Double Acting), Roller Material: M (Carbon Steel), Option: D (Locking Mechanism), Port and Lever Position: 0°, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Leadwire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: Air cushion on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With