SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R2-5B-1-Q"

Description TBR-1,2,3,4 TBR-A167 q Side plate PP TBR-1 TBR-A188 TBR-2 TBR-A168 w Branch pipe ABS TBR-3 TBR-A169 TBR-4 TBR-A170 TBR-1 TBR-A183 TBR-2 TBR-A184 e Fixing rod ABS TBR-3 TBR-A185 TBR-4 TBR-A186 TBR-1,2,3,4 TBR-A187 r Fixing plate PP 534

Refer to gauge guide (P.94). r w q w q Sample Order Number Port 2P 4PL 01 S BP10 e r t 0 4 4 4 4 1 MPA e 2P 4PL qIN wOUT erGauge port (Inlet) Specifications Operating Parameters BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1006 2 to 60 psig (0.014 to 0.4 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) BP1020 15 to

20 40 36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2 25 4 x M8 x 1.25 Effective

SMC VQZ2000-S-02T-Q subplate, 1/4 npt, VQZ2000 VALVE, SOL 4/5-PORT*** $10.45 Add to Quote Add To Cart Add to Cart SMC VQZ3000-GS-5 gasket/screw kit

No gauge port No pressure gauge No code 0 V3 L 1 H 2 4 Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.

4 4-1/4-28 UNF Depth 0.35 2-0.245 +0.0014 ~ 0 0.20 0.74 0.75 inch stroke 2-NPT1/8 Cylinder Port 1.30 1.38 Adjust Bolt ZZ Q SS Z S L Model F P 1.26 5 3.29 6.97 4.37 1.08 1.80 NCX2_25-100 1.15 1.00 0.83 7 4.29 8.97 6.37 2.08 2.64 NCX2_25-200 1.15 2.00 0.63 4-1/4-28UNF Depth 0.35 1/2-20 UNF 0.67 0.63 9 5.29 10.97 8.37 3.08 3.64 NCX2_25-300 1.65 2.00 4-32 Through Hole 11 6.29 12.97 10.37 4.08

, #1 CS1BQ160SCS1160, #1 The drawing shows with an auto switch style.

Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) 3 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 200/400 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200/400 VAC 5 q Ambient

Deionized water: Electric conductivity 1 S/cm or higher (Electric resistivity 1 Mcm or lower) 3 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 460 VAC 4 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 460 VAC 5 q Ambient temperature

Gauge port 2) (Inlete, Outletr) Porting Configuration Pressure gauge Code r psig/bar unit MPa unit r e No pressure gauge 0 6 10 20 40 60 Q w q w q 600 psig/bar 3) 4.1 MPa 7 MPa 14 MPa 28 MPa 41 MPa 70 MPa qIN wOUT eGauge port (Inlet) rGauge port (Outlet) Connections (Inletq, Outletw) 1000 psig/bar 3) Ports Code 2000 psig/bar 3) Connections 4P V 4PN e 4P 4PN 4000 psig/bar 3) 4 4B NPT 1/4 inch

psi [0.4 to 0.7 MPa] Proof pressure 145 psi [1 MPa] Lubrication Non-lube Cylinder for lock Weight [kg] 0.7 1 2 7 Operating Precautions Caution 1.

Place them in alphanumerical order. q e w Switch Characteristics Description Symbol Example) IS10-N01-6PZ Nil N Rc NPT q q Thread type Max. contact capacity AC 2 A, DC 2 W 24 V or less Note 1) Set pressure range of 6P(L, Z) is 0.2 to 0.6 MPa (30 to 90 psi). This product is for overseas use only according to the new Measurement Law.

Refer to pages 1590 to 1649 for the auto switches (e, r) and Best Pneumatics No.1-1 for the M8/M12 connectors (t, y). 1676

G V T Body type T Body ported O Manifold Thread type Rc G NPT NPTF Nil F N T Valve option Nil Standard type E Continuous duty type V For vacuum CE-compliant Nil CE-compliant Q Q Rated voltage CE-compliant: Electrical entry is applicable only for the DIN terminal. 1 2 100 VAC, Hz 200 VAC, Hz 50 60 50 60 3 4 5 6 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 7 240 VAC, Hz 50 60 50 60 Port size 50

RoHS Desktop Duster Box ZVB Series IZS How to Order IZN A S B ZVB 20 IZF ZVB ZVB q w e r t IZD IZE w Additional air blow B With additional air blow e Photoelectric sensor Nil None Note 1) S With photoelectric sensor Note 2) r AC adapter q Size Note 1) It is necessary to connect an external switch to the external input terminal on the back side of the product.

flow direction w 1000.0 LVP60 Flow rate Q [l/min] 100.0 With PVC unfixed union LVP50 Applicable to rigid vinyl chloride tube How to Order 10.0 LVP 5 0 16A 0.1 0.01 0.1 0.3 0.5 Differential pressure P [MPa] Series Valve type 0 1 2 N.C.

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C