SMC Corporation of America
Elite Part Number Search
Search Results "CDUJB10-10D-M9PS"

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 6mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 4mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 1 pc.

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 20mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 1 pc.

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 20mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 1 pc.

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 10mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 6mm, Rod End Thread: Rod End Female Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 1 pc.

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 4mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 1 pc.

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 4mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 8mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 15mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal

SMC's CJP series double acting pin cylinder's compact design minimizes mounting space. To accommodate many design styles, the CJP is available in five mounting styles: basic nose, foot, flange, clevis, and trunnion. An auto switch capable model is also available. Available bore sizes include 6, 10, and 15mm with strokes ranging from 5 to 30mm. Other features include brass panel mounting nuts

SMC's CJP series double acting pin cylinder's compact design minimizes mounting space. To accommodate many design styles, the CJP is available in five mounting styles: basic nose, foot, flange, clevis, and trunnion. An auto switch capable model is also available. Available bore sizes include 6, 10, and 15mm with strokes ranging from 5 to 30mm. Other features include brass panel mounting nuts

Shaft Type: W (Double Shaft with Single Flat), Size: 10, Rotating Angle: 180°, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Unit: CM [With Vertical Auto Switch Unit for D-M9 and Angle Adjustment Unit (Built-in Magnet)]