SMC Corporation of America
Elite Part Number Search
Search Results "DAS7-09"

D-sub Connector Type: B (26 Poles), Connector Entry Direction: 2 (Lateral), Valve Stations: 09, SUP/EXH Block Fitting Entry Direction: 2 (Side), SUP/EXH Block Port Size: N7 (ø1/4" One-touch Fitting, Straight), Mounting Option: N [Manifold Direct Mounting Type (10-32 UNF)]

Stations: 09 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve and Release Valve: K (N.C.

Stations: 09 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release Valve: K (N.C.

Socket/Plug: L (Semi-standard Socket), Thread Port Size: Not Applicable, Barb Fitting Port Size: 09 [8 Hose Nominal (1/4" I.D. Applicable Hose)], Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: B (w/Barb Fitting)

.: 09 (ø5/16"), Port Size/Applicable Tubing O.D.: 01 (R1/8), Thread Material/Surface Treatment: A (Brass), Sealant: P (Face Seal)

.: 09 (ø5/16"), Port Size/Applicable Tubing O.D.: 01 (R1/8), Thread Material/Surface Treatment: A (Brass), Sealant: P (Face Seal)

System/Body: Vacuum Pump System, Single Unit, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, -100 to 100, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø5/16" One-touch Fitting, Optional Specs. 1: -, Optional Specs.

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; None, Release Valve; None, Rated Voltage: When Combination of Supply Valve and Release Valve is N, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: "N" is selected for Combination

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common Wiring

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; Self-holding Release Valve Linked, Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, SI Unit Only, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; None, Release Valve; None, Rated Voltage: When Combination of Supply Valve and Release Valve is N, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; None, Release Valve; None, Rated Voltage: When Combination of Supply Valve and Release Valve is N, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø5/16" One-touch Fitting, Optional

System/Body: Vacuum Pump System, for Manifold, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø5/16" One-touch Fitting, Optional Specs. 1: -, Optional Specs

System/Body: Ejector System, for Manifold, Individual Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: Common Wiring, Plug-in for Manifold, Vacuum, V Port: Inch Size, ø5/16" One-touch

System/Body: Ejector System, for Manifold, Common Silencer Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; None, Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: Common Wiring, Plug-in for Manifold,