SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-T-M-C01-W"

Valve series Power consumption SY3000/5000/7000/9000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) SYJ3000/5000/7000 Standard: 0.4 W (approx. 17 mA) With power saving circuit: 0.1 W (approx. 4 mA) VQZ1000/2000/3000 Standard: 1.0 W (approx. 42 mA) Low wattage: 0.5 W (approx. 21 mA) Refer to "Wiring of the branch cable and connector for connecting load" on

Material Applicable blow gun model Model 6 copper extension nozzle Nozzle type P5670129-11 P5670129-11F HNBR Fluororubber VMG1mm-m-31 to 38 10 22 VMG1m-mm-31 to 38 5 Blow Gun X35 with extension and high efficiency nozzle Series VMG How to Order VMG 1 1 02 X35 W A Piping entry Nozzle Bottom 1 Nozzle part no.

Rc C4SF-6J-A G Rc C4SF-6-A G NPT C4SFN-6J(Z)-A NPT C4SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: "W" Standard Port thread type Part No. Rc C4SF-W-D G NPT C4SF-W(Z)-D Appearance and part No. Semi-standard: "6W" Standard Port thread type Part No.

Rc C4SF-6J-A G Rc C4SF-6-A G NPT C4SFN-6J(Z)-A NPT C4SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: "W" Standard Port thread type Part No. Rc C4SF-W-D G NPT C4SF-W(Z)-D Appearance and part No. Semi-standard: "6W" Standard Port thread type Part No.

Rc C4SF-6J-A G Rc C4SF-6-A G NPT C4SFN-6J(Z)-A NPT C4SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: "W" Standard Port thread type Part No. Rc C4SF-W-D G NPT C4SF-W(Z)-D Appearance and part No. Semi-standard: "6W" Standard Port thread type Part No.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: T (w

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter), Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Size: 16, Bearing Type: M (Sliding Bearing), Motor Mounting Position: D1 (In-line; Motor Cover Direction: Left), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R5 (5m), Controller: CM1 (CC-Link Ver. 1. 10), Mounting: 7 (Screw Mounting), I/O Cable: w/o Cable, Communication

Adapter z c Pad x W Pad W Horizontal lifting Vertical lifting This type of application should basically be avoided. 726

5 15-17-5 6 Series AS-FPQ/FPG Dimensions H (width across flats) Applicable tubing O.D. d A L4 D1 L3 D2 M1 L1 L2 T M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max. Min. Max. 1 2 Min.

Open Network Protocol SERIAL NETWORKS SOLENOID VALVE MANIFOLDS & DISCRETE I/O Protocol SI T ype No.

AL-OMX0056-A PRODUCT NAME Lubricator MODEL / Series / Product Number AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-D AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)06(B)(-2,3,6,8,R,W,Z)-D AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,W,Z)-D AL60-(F,N)10(B)(-2,3,6,8,R,W,Z)-D Contents Page 1. Safety Instructions 2-6 2. Application 7 3. Standard Specifications 7 4.

Electrical entry G H L LN LO Nil Grommet type, with 0.3 m lead wire (applicable to DC) Grommet type, with 0.6 m lead wire (applicable to DC) L plug connector, with 0.3 m lead wire L plug connector, without lead wire (applicable to DC) L plug connector, without connector (applicable to DC) Air operated/Without valve Pilot valve DC: 1 W (With indicator light: 1.05 W) DC: 0.45 W (With indicator

Do not use a cable longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.

Do not use a cable longer than 10 m. Wire the DC (-) line (blue) as close as possible to the power supply.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ DSince there are other applicable auto switches than listed, refer to page 697 for details. For details about auto switches with pre-wired connector, refer to pages 1014 and 1015. D-A9/M9/M9W/M9A(V) auto switches are shipped together (not assembled).

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, PRESSURE SWITCH, ISE1-6, 86 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 47.00000 lb