Speed-Workload graph > Wall Mounting Horizontal Mounting 6 6 LEL25L LEL25L Workload (kg) Workload (kg) 4 4 LEL25M LEL25M 2 2 0 0 0 500 1000 0 500 1000 Speed (mm/s) Speed (mm/s) -9- < Allowable dymamic moment graph > Workload overhang direction M:Workload[kg] L:Amount of overhang toward center of gravity of work piece [mm] Mounting direction Type LEL25M LEL25L 300 300 700mm 250 250 Overhang
Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21
Selection conditions Mounting: Horizontal Maximum speed: 500 mm/s Load eccentricity L1: 50 mm Overhang L: 30 mm Load mass m: 0.1 kg Refer to Graph 0 based on horizontal mounting, a speed of 500 mm/s and load eccentricity L1 of 50 mm.
51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 Bore 20 68 81 93 106 131 156 12.5 25 37.5 50 75 100 48 61 73 86 111 136 36 18.2 25 72 85 97 110 135 160 185 12.5 25 37.5 50 75 100 125 52 65 77 90 115 140 165 36 18.2 32 72 85 97 110 135 160 185 12.5 25 37.5 50 75 100 125 52 65 77 90 115 140 165 36 18.2 40
(AR300, 400, 500 only) Bowl can be attached and detached with one hand.
350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000 *Short stroke or intermediate stroke(except above stroke): Manufactured upon receipt of order 3.20-2 Compact Guide Cylinder Series MGC Specifications MGCll20 MGCll25 MGCll32 MGCll40 MGCll50 Model CDGIBA20 CDGIBA25 CDGIBA32 CDGIBA40
Slide table Note 4) The plots indicate the 95% upper reliability limit value for time series data up to 500 thousand operation cycles. (Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed.
Slide table Note 4) The plots indicate the 95% upper reliability limit value for time series data up to 500 thousand operation cycles. (Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed.
Slide table Note 4) The plots indicate the 95% upper reliability limit value for time series data up to 500 thousand operation cycles. (Cylinder: CYP32-200, Work piece weight: 5kg, Average speed: 2000mm/s) Note 5) The data above provide a guide for selection but is not guaranteed.
Flow Rate Characteristics Flow Rate Characteristics VBAT05A 2 1.6 0.1 ARJ 1.4 Outlet pressure (MPa) Outlet pressure (MPa) P1 = 1.0 MPa 1.2 P1 = 0.8 MPa Max. pulsation range (MPa) AR425 to 935 0.08 P1 = 0.75 MPa P1 = 0.7 MPa 1 P1 = 0.6 MPa P1 = 0.5 MPa P1 = 0.5 MPa 1 0.8 P1 = 0.4 MPa 0.06 ARX P1 = 0.3 MPa P1 = P2 0.6 P1 = P2 AMR 0.04 0.4 0.2 ARM 0.02 VBAT05A 0 500 1000 1500 2000 2500 3000
Max. load current Protection Built-in short circuit protection Current consumption 50 mA or less (inside a unit) Enclosure IP10 10 to 50C Operating temperature range Environmental resistance Operating humidity range 35 to 85%RH (with no condensation) EX Withstand voltage 500 VAC for 1 min. between external terminals and FG 10 M or more (500 VDC) between external terminals and FG Insulation
1,000 100 250 500 1,000 100 250 500 1,000 100 250 * 500 1,000 100 250 * 500 100 250 500 1,000 100 250 500 1,000 100 250 500 100 250 500 0.6 1.5 3 6 1.1 2.75 5.5 11 1.5 3.75 7.5 15 2.1 5.25 10.5 21 2.5 6.5 13 1.2 3 6 12 2.3 5.75 11.5 23 3.4 8.5 17 5 12.5 25 Features: 1/4 4mm Economical and lightweight LLDPE resin provides excellent environmental stress crack resistance Six colors Excellent
[mm] [s] 0 1 Pushing Absolute 9.00 0.50 2 500 2 Positioning Absolute 5.00 0.10 500 Controller Parallel input / output signals Flow chart (Reference) (1) Turn the SVON signal ON. (The motor is energized.) (2) Select/input Step No.1: Turn the IN0 input ON, and the "IN1"input OFF.
/ 100 ft@125 KHz (max.) 0.50 db / 100 ft@500 KHz (max.) 0.70 db / 100 ft@1 MHz (max.)
Cushion adjustment (relief adjustment) labor is the same as general purpose cylinder adjustment (cushion needle adjustment). 200 150 Cushioning quality (RHCF40-500, load weight 5kg, supply pressure 0.5MPa, horizontal drive) High power cylinder 500 General purpose cylinder Cushioning capacity [J] 100 1000mm/s 3000mm/s 2000mm/s 500mm/s 400 Stroke [mm] 300 50 200 100 50mm/s 20 25 32 40 50 63
1000 1500 0 200 400 600 800 00 25 50 75 100 125 150 0 0 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AC40-B Rc1/2 AC30-B Rc3/8 AC40-06-B Rc3/4 0.6 0.6 0.6 Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure [MPa] 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 500 1000 1500 Flow rate [L/min (ANR)] 0 1000 2000 3000 Flow rate [L/min (ANR)] 00
2000 2500 1500 1000 500 3000 3500 Air flow rate [L/min (ANR)] Air flow rate [L/min (ANR)] Specific Product Precautions 20 AMK Series Construction Size 20 to 40 q w OUT IN t Component Parts e No.
Refer to page 500 for CDA2-Z, page 557 for CDA2 and CDBA2. Dimensions (mm) D-G5NB 11.2 33 4 SMC 14 12 9.5 Indicator light 6.5 4.5 mounting hole DD14.3 Most sensitive position (16) 1619 Made to Order Specifications: Solid State Auto Switch Refer to SMC website for the details of the products conforming to the international standards.
PTFE (TF) option available for the AP 500, AP, AZ & AK 1000 & 1100 and AZ & AK 1300. The primary application for this material is for pressure regulators inside process tools. [Vespel] Trademark of DuPont Plastic with excellent heat resistance (polyimide resin). This material has excellent heat and wear resistance.
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !