SMC Corporation of America
Elite Part Number Search
Search Results "VM131F-03-06"

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 3/8-03-12AS3211FG-03-12-03-12-03-12

How to Order AW D 30 03 BE Body size Symbol Description 20 30 40 Nil N F 01 02 03 04 Nil Without mounting option B With bracket H With set nut (for panel mount) Nil Without auto drain C N.C. (Normally closed) Drain port is closed when pressure is not supplied. D N.O. (Normally opened) Drain port is opened when pressure is not supplied.

How to Order 30 03 BE AWD D Body size Symbol Description 20 30 40 Nil N F 01 02 03 04 Nil Without mounting option B With bracket H With set nut (for panel mount) Nil Without auto drain C N.C. (Normally closed) Drain port is closed when pressure is not supplied. D N.O. (Normally opened) Drain port is opened when pressure is not supplied.

03 03 03 3/8 04 04 04 04 1/2 4 + Nil Nil Nil Nil Without mounting option a Mounting B B B B With bracket H H H H With hexagon panel nut (for panel mount) + Pressure gauge Nil Nil Nil Nil Without pressure gauge Option Note1) G G G G Round type pressure gauge 5 EA EA EA EA NPN open collector 1 output b With digital pressure switch EB EB EB EB PNP open collector 1 output EC EC EC EC NPN open

Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 3/8-03-08AS3211FG-03-08-03-08-03-08

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 3/8-03-10AS3211FG-03-10-03-10-03-10

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 3/8-03-12AS3211FG-03-12-03-12-03-12

(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in8R 3/8-03-08AS3211FG-03-08-03-08-03-08

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

Applicable bore size B (C) (D) d H NT-02 20 13 (15.0) 12.5 M8 x 1.25 5 NT-03 25, 32 17 (19.6) 16.5 M10 x 1.25 6 NT-04 40 22 (25.4) 21.0 M14 x 1.5 8 Part no.

H Thread Size 1/16 NPT 33 Male 45 Elbow Cartridge 45 Elbow K 1/8 NPT 34 Male 90 Elbow Plug-In 90 Elbow Union 90 Elbow Cartridge 90 Elbow 1/4 NPT 35 L 3/8 NPT 36 1/2 NPT 37 3/4 NPT 38 Male Branch Tee Union Tee T Union 00 Male Branch Y Union Y Plug-In Y Plug-In 99 U Cartridge Q SAE 45 Flare S VD Male Double Universal 90 Elbow Y Male Run Tee Tube Size Z Male Branch Universal 90 Elbow 5/32 03

3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.

Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3

Electrical entry SC (T only) Type SU Type SC Type SC Type SU Type SC Type SU AXT622-5A AXT336-4AStations AXT336-5Stations Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod

Production label Product number MAC address Firmware and Hardware version Firmware version (FW): 1.0.x (X is a number 0 or more) Hardware version (HW): 03 and higher Fig. 6-2 Production label 6.3. PROFIsafe address switch An eight-bit DIP-Switch is provided for the F_Address of PROFIsafe. The switch setting is only checked at power-up.

Before Use Fieldbus system EX500-S 03 Wiring Product Summary LED Display Select the specified branch cable below.

Specifications Table 1 Specifications Model Item IP8101-03 Input current 420mADC 12 wire system, Separate power source unnecessary Minimum current 3.85mADC or more Voltage between terminals 12VDC Input resistance equivalent to 600, at 20mADC) Max supply power 1W 2 Imax:100mADC, Vmax:28VDC Supply air pressure 0.30.7MPa Standard stroke 601003 Sensitivity 0.2%F.S. or less 4 Linearity 1%F.S.

Power supply cable type/ IZG10-03 . 12 4. Function . 13 4-1. Name of parts . 13 4-2. LED indication . 13 4-3. Mode setting switch . 14 4-4. Emitter maintenance (cleaning and replacement) . 15 4-5. Alarm function . 17 5. Performance . 18 5-1. Installation distance and Discharge time (Discharge time of 1000V100V) . 18 5-2.

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing December, 1998 D-SMC.L.A. P-86.5 (JT)