MPa(G): 0.5, Leakage Pa•m3/s: Internal: 1.3 x 10-9 External: 1.3 x 10-11 , Internal: 1.3 x 10-9, External: 1.3 x 10-11, Connection Size: VVMW-2: 1/8 Female NPT / Face Seal VVMW-3: 1/4 Female NPT / Face Seal VVMW-4: 3/8 Female NPT / Face Seal , VVMW-2: 1/8 Female NPT / Face Seal, VVMW-3: 1/4 Female NPT / Face Seal, VVMW-4: 3/8 Female NPT / Face Seal
MPa(G): 0.5, Leakage Pa•m3/s: Internal: 1.3 x 10-9 External: 1.3 x 10-11 , Internal: 1.3 x 10-9, External: 1.3 x 10-11, Connection Size: VVMW-2: 1/8 Female NPT / Face Seal VVMW-3: 1/4 Female NPT / Face Seal VVMW-4: 3/8 Female NPT / Face Seal , VVMW-2: 1/8 Female NPT / Face Seal, VVMW-3: 1/4 Female NPT / Face Seal, VVMW-4: 3/8 Female NPT / Face Seal
Specifications Model ISE35 Rated pressure range 0 to 1 MPa Display/setting pressure range 0.1 to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption
11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32 40 50 63 2.7-6
Mark A Mark B Joint bracket Bracket for joining to adjacent units. 9 The unit is in normal operation. 10 Unit connector (Plug) Connector for signals and power supplies to adjacent units. Green LEDs are ON. 11 Connector (BUS IN) Connector for fieldbus inputs. Mark C on the unit Seal cap (2 pcs.) Fitted to unused connectors.
Hold/Clear/Forced ON Fail safe Short circuit protection Protection -10 to 50 oC (Max. surrounding air temeprature rating: 50 oC) Operating temperature Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. (2)Add more I/O units. Up to 10 units (including the SI unit) can be connected to one manifold.
"ALrto switch detail: see pgs. 10-11.
-2No.PS-OMF0005CN-E / 1 1.5 *3) 1 1 [] -3No.PS-OMF0005CN-E () () -4No.PS-OMF0005CN-E () * 5 m -5No.PS-OMF0005CN-E * (RcNPTG) 1/8 79 Nm 1/4 1214 Nm 1.52 2 * () ()() () () -6No.PS-OMF0005CN-E * IP66IP65 () 060 (5 ) * -7No.PS-OMF0005CN-E (ISA2 ) * * (EXH) 5 m 0.2 MPa CE (2 VCA ) () C-R () ()C-R ( ) () AC 10 DC 2 * * 2 0.51.25 mm -10+10 5 -8No.PS-OMF0005CN-E *
Mounted on to unused connectors (BUS OUT and PCI). 12 11 10 9 8 6 5 3 1 7 4 2 Direct mounting (1)When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4x5 screws. Tightening torque: 0.7 to 0.8 Nm. DIN rail mounting (Available for series other than SY series.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
Series VH Body Mounted/Dimensions VH600-06/10 2 (A) 4 (B) 1 (P) l152 132 4-11 132 300 223 151 150 48 25 4-Rc3/4, 1 3 (R) 40 3.6-11 Hand Valve Series VH Panel Mounted/Dimensions VH21l-02 VH31l-02 to 03 4 (B) 2 (A) 25 25 25 4 (B) SlA 1 (P) 3 (R) 1 (P) l74 l62 62 49 VlA 2 (A) 49 4-5.5 4-6.6 SlA VlA 62 134 97 VM/VR 125 94 VH 1.5 45 1.5 106 88.5 92 73 56 1 (P) 3 (R) 1 (P) 27 23 13.5
"ALrto switch detail: see pgs. 10-11.
Body size Metric size Inch size 3 4 5 6 1/8 1/4 3/8 1/2 07 09 11 13 06 08 10 12 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 01 02 03 04 1/8 1/4 3/8 1/2 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.
117 45 23 35 20 140 40 10 118 82 17 15 46 200 170 20 114 436 W-R3-SPosition of fulcrum 2 x 18.5 Proximity switch mounting bracket 74 Proximity switch (Option) 158 65 2 x Rc3/8 14 12 25 220 25 140 60 60 R5 50 118 160 270 210 60 2 x M8 x 1.25 thread depth 13 (External cover mounting screw) 4 x 11 10.5 (Clamp block mounting hole) 4 x 13 through 18 4 x 26 counterbore depth 9 2 x 8H7 +0.015 0
Liquid seals When circulating fluid Provide a relief valve in the system so that fluid does not get into the liquid seal circuit. 32 (11/4) 40 (11/2) 25 (1) 50 (2) Nominal dia. mm (inch) 4.0 6.0 8.0 12.0 Tightening torque Nm TLM TILM For fittings of 65A or larger, tighten the fittings by a further 1/8 rotation (45) with a belt wrench after tightening by hand.
D90 reverse unit Air gripper for auto hand changing system 20Variations Adapter for assembling robot Series MA2 8, 10, 11, 14, 15, 20 Series MA3 10, 11, 14, 15, 20, 24, 25 Additional installation unit of electrical contact point (Able to add 8 contact points) Air grippers for auto hand changing system (10 to 20) Standard type Narrow type 90 reverse unit Added to the standard AHC unit By attaching
12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.
D90 reverse unit Air gripper for auto hand changing system 20Variations Adapter for assembling robot Series MA2 8, 10, 11, 14, 15, 20 Series MA3 10, 11, 14, 15, 20, 24, 25 Additional installation unit of electrical contact point (Able to add 8 contact points) Air grippers for auto hand changing system (10 to 20) Standard type Narrow type 90 reverse unit Added to the standard AHC unit By attaching
rate (l/min(ANR)) Auto-drain 00 10 11 None 6 72 Float style auto-drain (N.C.)
ZSP ISA2 Auto shift function Refer to Technical Information on page 16-13-10. Failure predict output function Refer to Technical information on page 16-13-9. IS C Frequency response The inverse number of response time. The higher the frequency becomes, the shorter the response time becomes. ZSM Channel selection function Refer to Technical Information on page 16-13-11.