This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Air filter, mist separator and regulator unit , Clean looking, modular
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Air filter, regulator and lubricator unit , Clean looking, modular design
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 06 (3/4 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 5 μm, Element Seal Material: T (Fluororesin), Accessory: B (Bracket)
Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 04 (1/2 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 50 μm, Element Seal Material: T (Fluororesin)
Metric series T, nylon type, general air tubing is offered in 6 different colors. The T series is available in roll sizes 20m and 100m. The 100-meter rolls are available as standard in black and white only., TUBING, CUT LENGTH, TUBING, NYLON T/TIA, TS/TISA, 1.984 lb
2 16..25 0..7 See above See above PortConfig Por t 3 26..35 0..7 See above See above PortConfig Por t 4 36..45 0..7 See above See above -106No.EX-OMX1011 Parameter setting of IO-Link device with configuration assembly The Configuration assembly function enables PCL to send parameters to the IO-Link device, which is connected to the IO-Link master, under the EtherNet/IP communication connection
2 16..25 0..7 Refer to above Refer to above PortConfig Por t 3 26..35 0..7 Refer to above Refer to above PortConfig Por t 4 36..45 0..7 Refer to above Refer to above -111No.EX-OMZ0024 Parameter setting of IO-Link device with configuration assembly The Configuration assembly function enables PCL to send parameters to the IO-Link device, which is connected to the IO-Link master, under the
Appendix F: Safety Characteristics Operation Output with Two Output with Outputs Two Channel Single Channel Channel Single Channel (only) Input (only) Input (only) Item Input Input SFF 99.98% 99.98% PFDAV (T) 1% of 10-3 1% of 10-2 Average Probability of Dangerous Failure PFH (T) 1% of 10-7 1% of10-6 Probability of dangerous failure per hour Achievable Safety Level SIL3 / PL e SIL2 / PL d
/PL / 16 108 No.EX##-OMY0006CN 22.F + + SFF 99.98% 99.98% PFDAV (T) Average Probability of -3 1% of 10 -2 1% of 10 Dangerous Failure PFH (T) Probability of dangerous -7 1% of10 -6 1% of 10 failure per hour Achievable Safety Level SIL3 / PL e SIL2 / PL d SIL3/PL e SIL2 PL d 109 No.EX##-OMY0006CN 23.GEX245-FPS EX245-FPS1/2/3 Input delay : tFilter + 2 ms tFilter = Parameterized filter
Switch output T Temperature characteristics The amount of variation in the analogue output or display value when the ambient temperature is changed. U Function to change the unit in which the value of flow is displayed. Only a product with this function can change the unit. A product with unit selection function cannot be purchased if it is used within Japan.
Window comparator mode Bracket [F_2] Input the Set value of instantaneous output (Auto-preset) 34 mm Rc(NPT)1/4 12 to 14 Nm Selection of switch operation (OUT1) [1_n] Reverse output PF2W720(T) : This drawing is the model of PF2A710/750. 22 to 24 Nm Selection of switch operation (OUT2) [2_n] Reverse output Rc(NPT)3/8 PF2W740(T) ( ) Hysteresis Set point 2 Set point 1 Item Description Selection
Part number Description Remarks Weight ZS-37-A Lead wire and connector (Straight) Length: 3 m 100 g ZS-37-B Lead wire and connector (Right angle) Length: 3 m 100 g ZS-29-T Bracket Mounting screw (3 x 12 Self tapping screw) 4 pcs. 40 g ZS-28-CA-4 Sensor connector 1 pc. 2 g -11No.PF-OMO0010-C Summary of Product parts Connector pin numbers (on the product) 1 DC(+) 2 N.C.
PF2A551 12 to 24 VDC Blue DC(-) 22 to 24 Nm Rc(NPT)3/8 PF2W504(T) Piping port Connected to the fluid inlet at IN side and to the fluid outlet at OUT side. 1 5 Rc(NPT)1/2 28 to 30 Nm PF2W520(T) 34 mm Bracket Bracket for mounting the product.
Thus, when using these fluids type verity the fluid in advance by testing it, prior to making a decision to use it. 3: Refer to the T-file (PF-TDQ0010) too. Compatibility is indicated for temperatures at 90 oC or less. The product does not have an explosion proof construction.
V + (2m) N M L/min L G gal/min gal F gal/min gal J L/min L GFJ : 1[L/min]0.2642[gal/min] 1[gal/min]3.785[L/min] []=9/5[]+32 15 V PF3W5--1(T) -9No.PF-OMN0011CN-C C (1 ) T V -10No.PF-OMN0011CN-C / ZS-26-B ZS-26-C ZS-26-01 ZS-40-W 2 m (e-con) ZS-28-CA-4 1 ZS-40-Y 10 -11No.PF-OMN0011CN-C () () UP SET DOWN OUT1OUT2 ON UP ON/OFF SET DOWN ON/OFF -12No.PF-OMN0011CN-C
T Setting screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 28. Set communication range (simple communication protocol) with [] key or [] key, and press [SEL] key to enter.
Cable, connector, hub, please use the one that satisfies the standards of IEEE802.3 10BASE-T / 100BASE-TX. User's equipment can be connected up to four at the same time. Be sure to turn OFF the breaker of the facility power supply (the user's machine power supply) before wiring.
Cable, connector, hub, please use the one that satisfies the standards of IEEE802.3 10BASE-T / 100BASE-TX. User's equipment can be connected up to four at the same time.
Model number Serial number Type and quantity of refrigerant How to read the serial number y R 001 April 2020 W R 001 Year Symbol Remarks Month Symbol Remarks Serial no. 4 R Repeated from O to Z in alphabetical order, with O for January and Z for December 2020 y 2021 Z 5 S Repeat ed from A to Zin alphab etical order 2022 A 6 T Fig 1-1 Position of product label HRR Series 1.4 Product Label