3H9( ) depth 2.5 +0.025 0 3.2 3.2 6.3 7 7 12 1 A B NN x M4 x 0.7 thread depth 8 4 3H9 ( ) depth 2.5 +0.025 0 HA GA A-A B-B (mm) Model F 22 25 21 26 27 N 4 4 6 6 6 G 6 13 11 21 H 23 26 28 28 NN 2 2 3 3 3 GA 13 13 29 39 49 HA 16 26 20 28 28 I 9 9 9 16 9 J 17 27 37 48 65 K 21.5 31.5 41.5 51.5 61.5 M 42 52 62 80 90 Z 41.5 51.5 61.5 79.5 89.5 ZZ 64 74 84 102 112 13-/22-MXQ6-10 13-/22-MXQ6-20
Description Material Note O-ring O-ring NBR NBR Body B Brass Electroless nickel plated Body B Brass Electroless nickel plated O-ring O-ring NBR NBR POM (2) Needle Brass Electroless nickel plated Seat ring Brass Electroless nickel plated Spring Steel wire U seal HNBR U seal HNBR Cassette POM, Stainless steel (1) Gasket Spacer NBR, Stainless steel Tool steel Retaining ring for hole type C Note
9 to @2 20Solenoid valve with adapter assembly SYJ3 3-M VZ5 4 -M VF3 4 -M VZ3 4 -M A B A B A B A B @3 Data Note 1) Seal kit includes !9 to @2. Order the seal kit, based on each bore size.
The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Max. pressure H_1 = (A B)/2 H_1=(A B)/2 B = Min. pressure The display of set values of OUT2 is changed at the number after "_", i.e. "P_2", "n_2" and "H_2". -33No.PS-OMM0003-J [F 9] Power saving mode Power saving mode is selectable.
Metal bowl B B B B B Dimensions B B N.C.: Gray N.O.: Black B 1/8 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 M5 x 0.8 Width across flats 17 Width across flats 17 Standard specifications Bracket mount Model Port size A B C D P E F G H1 H2 J K L L M (1) (1) (1) (1) ACG20 ACG30 ACG40 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 5.5 3.2 1/4, 3/8 167 115 41 80 30 55 57 41 35 35
Specify the quantity of units necessary for use with your piping system. 29 Series HRG Dimensions [Dustproof filter set] HRG-FL001 HRG-FL005 A A (10) (25) (25) B (25) (25) (10) B Surface fastener HRG-FL010 A (10) (25) (25) B (390) (390) HRG-FL015 A (10) A (10) (25) (25) (25) (25) B (Large) (Small) B (390) (390) (mm) A B C Part no.
Free flow 0.2 0.3 0.3 0.4 0.4 0.3 0.3 b values: Critical pressure ratio Controlled flow 0.2 0.3 0.3 0.3 0.3 Note) C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed. 625 AS Series Brass Elbow Universal Electroless nickel plated How to Order 1 2 0 U01 A F AS 2 06 Push-lock type Body size Applicable tubing O.D.
Refer to pages 1745 and 1746 for details. 25 46.5 34.5 30 55 43 10 31 19 31 19 15 36.5 24.5 5 25.5 26.5 13.5 14.5 10 30.5 31.5 18.5 19.5 A B C D A B A B A B A B MXP8 DMXP6 MXP10 -X MXP12 Individual -X MXP16 Note) Adjust the auto switch after confirming the operating conditions in the actual setting. 209 Series MXP Specific Product Precautions 1 Be sure to read before handling.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
E MM GA D J C 2.8 A Width across flats L 2-P through A1 H E 4-T counter bore 0.5 B S Z (mm) S Z T QA R Q A A1 P GB MM B C D E GA L J H GC Bore size 5 30 40 50 5 10 15 20 25 30 40 50 15 20 25 10 4.5 2 16 12 9 4 20 16 12 11 5.5 4.5 26 20 40 32 8 6 30 27 6 5 16 14 19 16 22 19 21.5 19 116 126 135 145 M6 x 1.0 M5 x 0.8 14 12.5 40 36.5 81 72.5 86 77.5 91 82.5 96 87.5 101 92.5 106 97.5 100
Contents 20 MGP20-B-PS Set of nos. above @4, @5, @6, @7, #5, $4, $5 50 MGP50-B-PS Set of nos. @4, @5, @6, @7, above #5, #6, $4, $5 63 MGP63-B-PS 80 MGP80-B-PS Set of nos. @4, @5, @6, @7, above $4, $5 100 MGP100-B-PS 25 MGP25-B-PS 32 MGP32-B-PS 40 MGP40-B-PS *: Each seal kit includes the parts listed above.
Contents Contents 20 25 32 40 50 63 80 100 MGP63-B-PS MGP80-B-PS MGP100-B-PS MGP20-B-PS MGP25-B-PS MGP32-B-PS MGP40-B-PS MGP50-B-PS Kits include items 21, 22, 23, 24, 32, 33, 41 and 42 from the table above. Kits include items 21, 22, 23, 24, 32, 33, 41 and 42 from the table above. Items 32 and 33 are not included for bores sizes 80 and 100.
Slide Bearing Felt Holder Ball bushing Spacer Aluminum alloy Replacement Parts: Seal Kit Bore size (mm) Contents Kit no. 20 25 32 40 50 MGP20-B-PS MGP25-B-PS MGP32-B-PS MGP40-B-PS MGP50-B-PS Set of nos. above @1, @2, @3, @4, #2, #3, $1, $2 Seal kit includes @1 to @4, #2, #3, $1, $2.
J Q F Z Stroke 32 40 50 RSQB -DZ (Double acting) Bore size: 32, 40, 50 M E J 2 x P (Rc, NPT, G) T 0 0.1 D Q F Z Stroke M E J T 0 0.1 D Width across flats K A + 2 stroke B + Stroke V H + Stroke 2 x P (Rc, NPT, G) E M 4 x N through 8 x O counterbore Q F Z Stroke T 0 0.1 Width across flats K A + 2 stroke B + Stroke V H + Stroke D M E J E M 4 x N through 8 x O counterbore Width across flats K
5 A-A t y @2 C B e @1 !0 C B r w C-C B-B !4 !2 Body Table !3 Component Parts No. Description Material Note No.
B D Purge air discharge tubing port for dehumidification Applicable tubing O.D.: J (NPT threads: K inch) Purge air for Purge air for dehumidification dehumidification (Maintenance space 100 mm or more) Option: P Port size L A B C D E Model F G J H K IDG10, 10H IDG20, 20H Values inside [ ] are for NPT threads. 83 187 53 165 62 97 224 119 [126] 8 5/16 1/4, 3/8 113 212 54 190 82 114 249 147
A 3.2 6.5 7 7 15 1 3H9 ( ) depth 3 +0.025 0 4 NN x M4 x 0.7 thread depth 8 B A 3H9 ( ) depth 3 +0.025 0 HA GA Section AA Section BB (mm) ZZ 74 79 90 108 126 176 M 49 54 65 83 101 151 Z 48.5 53.5 64.5 82.5 100.5 150.5 K 23.5 33.5 43.5 53.5 63.5 88.5 J 19.5 29 39 56 60 96 I 13 8.5 9.5 10.5 24.5 38.5 NN 2 2 3 3 4 5 HA 20 30 20 28 46 56 H 28 30 20 28 23 28 GA 17 12 33 43 43 83 G 9 12 13 15 20
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
(G) B D Purge air discharge tubing port for dehumidification Applicable tube O.D.: J (NPT thread: K inch) Purge air for dehumidification Purge air for dehumidification (Maintenance space 100mm or more) Option: P Port size L A B C D E Model F G J H K 97 224 8 119 [126] 5/16 114 249 10 147 [154] 3/8 83 187 53 165 62 113 212 54 190 82 IDG10, IDG10H IDG20, IDG20H Values inside [ ] are for NPT