Type), Vacuum Pressure Sensor: D (Digital Vacuum Pressure Switch), Output Specifications: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: P (w/Unit Switching Function, Initial Value psi, Not for Use in Japan), Lead Wire Specifications: L (Lead Wire w/Connector, 2m)
(October 1999) (3) Lead wire specifications Nil No lead wire with connector W Lead wire for energy saving switch (2 m) (4) Fitting (V port) 0 Without fittingM5x0.8 1 3.2Straight 2 4Straight 3 6Straight 4 3.2Elbow 5 4Elbow Lead wire with connector for energy saving Pressure switch assembly ZQ1 LW6 N A (1) (1) Output N NPN open collector P PNP open collector 9 - NO.
P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc. P tight screw (4 x 14), 2 pcs. (3)Intermediate support bracket EX600-ZMB1for direct mounting Enclosed parts: Round head screw (M4 x 5), 2 pcs.
Note Platinum silver Platinum silver Black Black q Description Sub-plate Body Aluminum die-casted Stainless steel w e Mounting bolt and gasket are not attached. : Thread type Spool/Sleeve Adapter plate Thread Type r Resin t Resin End plate Nil Standard Rc y Resin Piston NPT N Option T NPTF G F Replacement Parts Description Material Part no. No.
Find the moment of inertia I for the rotation of shaft (B). r B 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth = b 5. Solid sphere Position of rotational axis: Through the center of diameter r 2 2 r I = m5 -27- Kinetic energy Table shows the allowable kinetic energy of the rotary actuator.
L1 A1 Mr Static moment Dynamic moment Graph (1) Load Mass: W W W MXJ4 A3 L3 L2 A2 0.10 L3 A3 Rubber stopper Mr Load mass W kg Mp 0.08 My Metal stopper W 0.06 W W 0.04 Mey Mep We 0.02 We L3 L2 A2 0.00 Collision speed V mm/s (Average speed x 1.4) 0 200 100 300 400 500 600 700 A3 MXJ6 Note) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with
2 w y r !0 e 1 New PFA Body 2 New PFA Sensor 3 Super PFA Tube 4 PPS Housing A 5 PPS Housing B 6 PPS Housing C 7 POM Bushing 8 PPS Cap 9 FKM Gasket 10 FKM O-ring 11 SUS304 Thread 12 PVC Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !
One set of diaphragms monitors the pressure differential and operates the micro switch through the rod w and operating lever r. The rod w moves downward with increased flow, and upward with decreased flow. Moving the gear t upward or downward by the adjusting gear e manually offers an electric signal at various flow rates.
(reference value) 11-LEJS40* Speed 600mm/sec Speed 1200mm/sec 100,000,000 100,000,000 10,000,000 10,000,000 ISOclass8 ISOclass8 0/mi n( AN R ) ISOclass6 1,000,000 1,000,000 ISOclass7 ISOclass7 Particl concentration[Particls/m 3] Particl concentration[Particls/m 3] 100,000 100,000 0/mi n( AN R ) ISOclass6 10,000 10,000 ISOclass5 ISOclass5 50/mi n( AN R ) 20/mi n( AN R ) 1,000 1,000 ISOclass4
Description Remarks Usable load wattage is limited to 1.5 W because power is supplied by the SI unit. When the load is up to 12 W, use both the Power block and a high wattage load Output block. For low Current Output to connected load (output equipment) or manifold valves using the power supply from the SI unit.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: B2 [TSJ1/4 (Compression Fitting)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)]