B LVM1 (Rocker type) 3 port Universal LVM115 PAT.PEND A Dead volume B Body and plate material: PEEK C Diaphragm material: EPDM, FKM or Kalrez Bracket (Optional) Features 2 Diaphragm Type Direct Acting 2/3 Port Solenoid Valve for Chemicals Series LVM10/100 How to Order Series Number of ports Symbol Valve type Connection Wetted part material 11 N.C.
Smooth Cylinder Series CQSY 12, 16, 20, 25 How to Order B 20 D 30 C CQSY M9BW B D 20 30 C CDQSY With auto switch Number of auto switches Nil S n With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Nil S n No Perpendicular to the cylinder axis D With auto switch (Built-in magnet) Nil For a cylinder with D, -B is suffixed to the end of the part number. Type of auto switch Axial direction R Nil Without auto switch For applicable auto switches, refer to the Applicable Auto Switch table.
Nil S n Nil Without auto switch B A L F G D Through-hole (Standard) Both ends tapped style Foot style Rod flange style Head flange style Double clevis style For the applicable auto switch model, refer to the table below.
P_1 = A-(A-B)/4 A = Maximum pressure value H_1 = | (A-B)/2| B = Minimum pressure value To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or longer. 28 - NO. ZQ-OM01501 [F 6] Fine adjustment of display value This function is used to manually perform fine adjustment of the displayed pressure. It is adjustable within the range 5% R.D.
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. -2- . / 1 1.5 *3) *3) 1 1 () -3- IR1000 (1) 0.2% F.S.
1.41.6Nm 8 2 VR2110 3 01.0MPa 0.250.8MPa 0.560s (*) 10 (%) F.S. oC( -560 3/ (s C (dm 0.6 [1 (P) 2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec
Cylinder Bore Size MHS 2 D 50 32 to 63 Y59A Number of auto switches Nil S 2 pcs. 1 pc.
Slide the table forward. 2 B Always detect ON Adjust the switch position according to loads or speed. (Unit:mm) B A 2 2.5 4 5 5.5 10 Model MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 1 3 17 MXF Series Low Profile Slide Table Operation Guide Slide table mounting Cautions on use The table is supported by precision bearings.
0 q 4 Series LVR Dimensions Integral ttings/LQ3 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Model A B C D E LVR20-Z07(06) 40 40 49.3 68 20.1 LVR40-Z11(10) 82.5 82.5 89 115 33 LVR40-Z13(12) 82.5 82.5 89 115 33 LVR50-Z19 100 100 117.5 135 45 Breathing port M5 x 0.8 IN Model F G H J LVR20-Z07(06) 8 27 56 88 LVR40-Z11(10) 14 64.5 100 150.5 LVR40-Z13(12) 14 64.5 100 159.5 LVR50-Z19
WQ Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Description Material Note ASR ASQ Body A Body A 1 1 PBT PBT Body B Elbow body Electroless nickel plated 2 2 Brass PBT Needle Body B Electroless nickel plated Electroless nickel plated 3 3 Brass Brass Needle Seat ring Electroless nickel plated Electroless nickel plated 4 4 Brass Brass Seat ring Spring Electroless nickel plated Steel wire (1) 5 5 Brass U seal Spring Steel wire (1) 6 6 HNBR
-C D-T791C D-T792C -21No.D-S-OMB0023-C D-S991/D-S9P1/D-T991 D-S992/D-S9P2/D-T992 -22No.D-S-OMB0023-C D-S99V1/D-S9PV1/D-T99V1 D-S99V2/D-S9PV2/D-T99V2 -23No.D-S-OMB0023-C Pre-wired connector D-#APC/D-#BPC D-#DPC -24No.D-S-OMB0023-C Revision history A: Limited warranty and Disclaimer are added.
No Key operation LED Display (1) Deactivate the key lock if necessary (see page 22). (2) Press S-key for 2 seconds or more, then go to detail setting mode. (3) To "F99" by using the and keys. (displayed alternately) (4) Press S-key. flashes on the display (5) Press and S keys for 5 seconds or more. (press S-key to (3)) is displayed (6) "Initialize" is executed, after 5 seconds.
CANADA INSTRUCTION MANUAL REFRIGERATION AIR DRYERS PDE 3-S PDE 5-S PDE 8-S PDE 10-S PDE 15-S PDE 20-S AIR COOLING SYSTEM ISSUE EDITION 2000 GB Dear Customer, thank you for choosing our product. In order to get the best performances in the use of this product, please read carefully this manual.
8370: JIS B 8361: JIS B 9960-1-(1 : ) JIS B 8433*2) : : : 1. 2. 3. 1. 2. 3. 4. -2No.EX-OMQ0015CN / 1 1.5 3 3) 1 1 -3No.EX-OMQ0015CN () () () () -4No.EX-OMQ0015CN / () * UL UL1310 Class2 0V -5No.EX-OMQ0015CN * IP67 / *() () ( ) * IP67 M12(M8) ( ) () -6No.EX-OMQ0015CN CE * PLC PLC * -7No.EX-OMQ0015CN EX600 SI 1 SI3210SI U SI D SI ON/OFF PNP NPN PNP NPN
Short circuit Signal is either short circuited to another signal or 0V. 40 No.EX##-OMY0011-A Appendix B: Parameters for PROFIsafe F-parameters The values indicated in italics in Table are preset by the system and cannot be modified manually.
Hexagon socket head cap screws. (2) Loosen hexagon socket head cap screws, Body B and then remove them from the Body A. Body A Guide bolt (3) Push the seal support so that the rod cover comes out of the Body B end surface. Rod cover Seal support Body B (4) Remove the lever shaft and lever. Lever shaft Lever (5) Pull out the rod cover and piston assembly and replace the seal.
2 Safety Instructions Continued 1) Inspection and maintenance of machinery/equipment should only be 3 Specifications Continued 3 Specifications Continued HEC-OM-U015-B HECR012-W performed after confirmation of safe locked-out positions.
4 O-ring Body B NBR Stainless steel 303 r !5 O-ring Body B NBR Stainless steel 303 t !6 Needle O-ring NBR Stainless steel 303 y !7 O-ring Seat ring NBR Stainless steel 303 u !8 O-ring Needle guide NBR Stainless steel 303 i !9 Gasket Lock nut M5 type only NBR, Steel Stainless steel 303 o @0 Lock nut Spacer PBT Note) Stainless steel 303 !