Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: Standard, Attachment: TV (T + V), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: GH (G + H), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: N (NPT), Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 10 (ø10), Seal: S (w/Sealant)
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: B (Out 1: PNP; Out 2: PNP), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: DM (D + M), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Model: 520 (2.0 to 16.0 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), I/O Specifications: A1 (IN1: 1-5 VDC, IN2: External Control Input, OUT1: 1-5 VDC), Lead Wire: C (Lead Wire with M12 connector, 3m, Bracket: N (None), Operation Manual: Z (with Operation Manual)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 0°, Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 11 (ø3/8"), Seal: S (w/Sealant)
1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
Series: AFD, Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Mounting: Standard, Float Type Auto Drain: w/o Auto Drain, Bowl Type: Standard (Polycarbonate Bowl ), Bowl Guard: None, Drain Port: J (Drain Guide 1/8: Body Size 20; Drain Guide 1/4: Body Size 30, 40), Indicator: without Indicator, Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Z (Pressure Unit
1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;
Body Size: 3, Set Pressure: 1 (1.5 to 58 psi [0.01 to 0.4 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 04 (1/2), Option: EB (PNP Open Collector, 1 Output), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 04 (0.5~4L/min), Return Unit: None, Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Size: 4 (3/8), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 1 (0.05 to 0.7MPa), Relief Function: 0 (Non-relieving), Thread: Rc(PT), Port Size: 04 (Rc 1/2), Direction of Gauge Port: R (Right)