PA + Stroke GB Q G J K IE S XAH7 depth XL (mm) MLGPM, MLGPL common dimensions Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA IB IC ID IE 14 11 100 44 16 12 44 54 10 120 M6 34 52 14 4 14 40 25, 50, 75 100, 125, 150, 175 200, 250, 300, 350 12 13 107 44 20 16 47 64 148 M8 35 64 19 50 11 7 14 115 49 20 16 50 78 162 M10 38 77 19 63 16.5 16.5 13.5 6.5 16.5 Bore size (mm) J
For details, refer to page 8-30-32. 8-20-11
B + Stroke A + Stroke FA FB S HR E b a With front lock XAH7 c d e MO XB T-slot dimensions (mm) DM HN XAH7 XC XL Bore size (m) a b c d e End lock mechanism (locking type manual release ) 6.5 10.5 5.5 3.5 9.5 32 Section XX detailed diagram 6.5 10.5 5.5 4 11 40 8.5 13.5 7.5 4.5 13.5 50 11 17.8 10 7 18.5 63 LL With rear lock (mm) Standard strokes (mm) Bore size (mm) ML NN OA B C DA FA FB G GA
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.
Y69B 3 m L Y69BL 5 m Z Y69BZ IC circuit 2-wire Y59B Y69B Solid state switch 12 V Relay PLC Grommet 24 V Yes 3-wire (NPN) 3-wire (PNP) Solid state auto switches marked with a are manufactured upon receipt of order. Y7NW Y7NWV 5 V 12 V Diagnostic indication (2 color indication) IC circuit Y7PW Y7PWV Refer to page 8-30-1 for detailed auto switch specifications.
Also make sure that the rotational torque applied to the cylinder body does not exceed the allowable rotational torque (given on page 11). (Otherwise, the excessive rotational torque will damage the non-rotating mechanism and lead to a malfunction.) 6.
The MHL2-Z series (bore sizes 10, 16, 20, and 25) was released in December 2016. The MHL2-Z series air gripper dimensions and mounting dimensions are interchangeable with the existing product. Only the round type auto switches (D-M9 □) with a round switch groove can be mounted on the product.
Nil S MHW -X Tool stand MA210 Y59A S1 MRHQ MA Tool stand DAuto switch type Lead wire length Without auto switch Nil Nil L Grommet With 0.5 m lead wire With 3 m lead wire D-Y59A (3-wire) Y59A Solid state auto switch Lead wire: Axial direction entry D-Y59B (2-wire) Y59B 741
AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Pre-wire connector Wiring (Output) Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire (NPN equivalent) IC circuit Z76 5 V Reed switch Solid state switch Yes Yes Grommet 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW Relay, PLC 3-wire (NPN) 2-wire Y69A Y7PV
11 Common for each auto switch Since this is a guideline including hysteresis, not meant to be guaranteed.
11 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 45 64 11.7 6 11 6.6 M8 x 1.25 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load. In such a case, use a side support in the middle section.
11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 84 90 98 116 126 146 159 170 204 215 16
If a greater rotational torque is applied, the non-rotating rod (page 4) bends, exceeding the value of the nonrotating accuracy. 11 Guide Table Series MGF Operating Conditions Allowable eccentric load The maximum value of load which can be applied at an eccentric position at a distance of l (mm) from the cylinder center.
As a rough guide, tighten the screw an additional 90C after feeling a tight resistance. 4.3-11 Lever Detection Switch (Proximity Switch) Mounting Position Proximity Switch Specifications/Manufacturer: OMRON Co. Ltd. E2E-X1C1 E2E-X2D1-N Model no.
wire length (m) Special function Electrical entry Indicator light Wiring (output) Applicable loads Electrical entry direction Type 0.5 (Nil) 3 (L) 5 (Z) DC AC Perpendicular In-line 3 wire Z76 5V IC circuit Yes Relay, PLC Reed switch Z73 Grommet 100V 12V 24V 2 wire 5V, 12V 100V or less Z80 IC circuit No 3 wire (NPN) 3 wire (PNP) Y69A Y59A 5V, 12V IC circuit Y7PV Y7P 2 wire Y69B Y59B
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The tightening torque should be approximately 0.05 to 0.1 Nm. 8-17-11 11 Series CYP Specific Product Precautions 1 Be sure to read before handing. Operation Handling Caution Caution 1. Open the inner package of the double packaged clean series inside a clean room or other clean environment. 2.
1 Series MHL2 Auto Switch Installation Example and Mounting Position Auto Switch Series MHL2 Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions. 2) Detection when Gripping Interior of Workpiece Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions