Refer to the attachment table on page 14-2-12 or 14-2-16 for standard bypass port sizes applicable to AC.
Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3
size: 63, Arm opening angle: 90, Distance to the center of gravity L: 250 mm Calculation example With an arm opening angle of 90 and a 250 mm distance to the center of gravity, according to the graph, the maximum allowable load mass is 4.0 kg. 10 CKZ3N -X2742A -X2568 Setup Procedure Precautions 1) The tightening torque of the clamp arm is 12 to 15 Nm for 50 and 15 to 20 Nm for 63.
B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521-12/14 50 250 PF3W521-U30 30 250 () A B C D 0.6 V 1 V 5 V 5.4 V -40No.PF-OMN0009CN-F PF3W504/520/540/511 2X A AA B DD E F G H J K L N P PF3W504 3/8 70 50 30 45.6 40.6 15.2 24 14 35 26 18 13.6 2.7 14 PF3W520 3/8 1/2 78 54 30 45.6 40.6 15.2 27 18 39 30 18 13.6 2.7 12 PF3W540 1/2
Optional specifications Note 1) With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B B B U AC20D AC30D AC40D AC40D-06 160 209 208 214 234 38 247 246 251 272 45 250 249 255 272 45 12 F.R.L.
Please change the parameter in the initial setting. *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 12 - LECSS LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter Para. No.
Optional specification Note 1) With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B B B AC20D AC30D AC40D AC40D-06 160 214 234 208 209 246 251 272 247 275 250 249 255 12 F.R.L.
, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact SMC if the maximum stroke will be exceeded.
Nil 20, 25, 32, 40 TN TF Standard stroke Refer to page 12 for standard stroke.
No Initial value Recommended value Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 65536 114688 32768 65536 Electronic gear denominator *3 PA07 1 250 125 125 125 250 125 125 Regenerative option PA02 0 0 (Non)/ 0002 (LEC-MR-RB-032)/ 0003 (LEC-MR-RB-12) 1 Rotation direction selection *4 PA14 0 0 (+Counter motors side ) (+Counter motors side
Maximum acceleration: 2000mm/s2 Positioning distance (mm) 1200 600 100 10 1 120.5 60.5 10.5 1.5 0.5 10 Speed (mm/s) 12.5 6.5 1.5 0.6 0.5 100 5.4 3.0 1.0 0.6 0.5 250 3.1 1.9 0.9 0.6 0.5 500 A B C D Values will vary slightly depending on the operating conditions. 157 12 Series LG1H21 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588
300 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 32 50 105 80 MGQ 70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 38 60 125 95 45 194 42 M10 200 95 12 11 135 115 210 190 82.5 19 23 142 50 75 150 115 MGG Bore (mm) Z Y X W WH W V U T S R Q O P MGC 20 25 32 40 50 140 80 30 30 23 36 40 86 12 26 12 21 M6 X 1 M5 X 0.8 MGF 153 80 37 30 25 44 47 98 13 31 12 21 M6 X 1 M5 X 0.8 161 82
CURRENT RATING LISTED IN CATALOG UL/CSA RATING 15A 15.1 Amps and 1/2 HP, 125 or 250 VAC. 1.2 Amp, 125 VDC; 1/4 Amp, 250 VDC 5 Amps, 120 VAC "L" (lamp load) 10A 10 Amps and 1/4 HP, 125 or 250 VAC. 1/2 Amp, 125 VDC; 1/4 Amp, 250 VDC 3 Amps, 125 VAC "L" (lamp load) 4A 4 Amps, 250 VAC 1/10 HP, 125 VAC 3A 3 Amps, 125, 250, 277 VAC 1/10 HP, 250 VAC Gold Option .1 Amp, 125 VAC MATERIAL APPROVALS
, 12 V 12 V IC circuit Terminal conduit M9NW 3-wire (NPN) Relay PLC Yes G59W 5 V, 12 V Diagnostic indication (2-color indicator) IC circuit M9PW 3-wire (PNP) G5PW 24 V M9BW 2-wire 12 V K59W Grommet M9NA1 M9PA1 M9BA1 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Water resistant (2-color indicator) 12 V 2-wire G5BA G59F F59F 4-wire (NPN) 5 V, 12 V IC circuit IC circuit Diagnostic output (2
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 285.5 21 273 No.
V 12 V IC circuit Diagnostic indication (2-color indicator) Relay, PLC IC circuit 5 V, 12 V 12 V Yes Yes No Grommet 24 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V A96V A96 IC circuit 5 V 12 V Grommet 24 V A93V2 A93 A90 100 V Relay, PLC 2-wire A90V IC circuit 100 V or less 1 Water resistant type auto switches can be mounted on the above models
38 12 14 EXH Port Size 12 14 38 38 12 INSTALLATION Pilot EXH Port Size 18 The Booster Regulator should be installed with its piston in a horizontal position.
NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) Reed switch Solid state switch A96V A96 5 V IC Yes Yes Grommet A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 100 V 24 V 12 V Relay, PLC 5 V, 12 V IC 12 V 5 V, 12 V IC Relay, PLC 24 V Grommet 12 V Diagnostic indication (2-color) 5 V, 12 V IC 12 V 2-wire
NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) Reed switch Solid state switch A96V A96 5 V IC Yes Yes Grommet A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 100 V 24 V 12 V Relay, PLC 5 V, 12 V IC 12 V 5 V, 12 V IC Relay, PLC 24 V Grommet 12 V Diagnostic indication (2-color) 5 V, 12 V IC 12 V 2-wire
RLQ MLU View A-A' ML1C DStandard Stroke B AF AP E A AA AB AC AD AE BP BZ C D F G GC Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 32 35 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 28 135 118 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 19 104 75 37 40 50 29 160 140 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5