w r w e e VXF26C<r r e q e q VXF26D<r w r w e q e q Component Parts Component Parts No.
Applicable flange size Applicable tubing size (mm) 2 4 4 5 5 5 6 6 6 Size Symbol Applicable flange size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 6 x 4 1/4" x 5/32" 2 2 3 1 2 3 2 3 4 B B C A B C B C D LVW 12 x 10 1/2" x 3/8" LQ1 19 x 16 3/4"
Applicable model Minimum operating flow rate (50/60 Hz) [L/min] HRS-BP005 HRS090-ll-20/40 29/45 To circulating fluid return port r t r e q To circulating fluid outlet r t w r Parts List No.
indicator light: DL) Main port Rc A B C D E F G H I J K L M N P Q R S T U V W Model VNB2V-10A VNB2V-15A VNB3V-20A VNB4V-25A 3 8 1 2 3 4 1 63 42 28 14 72.5 80.5 75 87 97 114 126.5 170.5 173.5 180.5 52 26 4.5 24.3 2.3 25 34 55 80 90 50 60 35 40 17.5 20 84 100 92 108 80 81 92 93 102 103 125.5 141.5 138 154 182 198 185 201 192 208 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 60.5 73 17-
Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U VNB2-10A VNB2-15A VNB3-20A VNB4-25A 3 8 1 2 3 4 1 144.5 55 125.5 52 26 4.5 24.3 2.3 25 34 63 42 28 14 72.5 80.5 75 80 84.5 124 60.5 73 135.5 151.5 137 153 156 172 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 80 90 50 60 35 44 17.5 22 84 100 92 108 84 90 89 95 93.5 99.5 Port size: 10A, 15A, 20A, 25A Vacuum pilot K L N
Applicable piping size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 2 2 3 1 2 3 2 3 4 B B C A B C B C D 6 x 4 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 1/4" x 5/32" 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 12 x 10 1/2" x 3/8" 19 x 16 3/4" x 5/8" 25 x 22 1" x 7/8" Dimensions Union Flange: LQ3F Metric Size (S) T P M L2 L2 L1 L1
VCC 0.4 0.3 TQ 0.2 0.1 0 1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Operating pressure (MPa) 619 A VNC Series Construction N.C. i i o o t t r w r w Port 12(P1) Port 10(P2) u u In the case of 32A to 50A y y N.C.
Specifications Model Nominal thread size Allowable axial force [N] Allowable eccentricity U [mm] Rotating angle [] Operating temperature range JT20 M8 x 1.25 220 0.5 2 10 to 70C JT32 M10 x 1.25 560 0.5 2 JT40 M14 x 1.5 880 0.75 2 Operating range Center of sphere e g 2 n a Center of axis r U U g n ti a 2 r e p O Applicable Cylinder Model Applicable cylinder *1 Recommended cylinder Bore size
FKM/EPDM O-ring e O-ring e 10A to 25A 15A to 25A Diaphragm assembly Diaphragm assembly Stainless steel, Brass, NBR Stainless steel, Brass, NBR r r Stainless steel, Brass FKM/EPDM 32A to 50A 32A to 50A Valve spring Valve spring Stainless steel Stainless steel, Copper Stainless steel, NBR Stainless steel Class B molded Stainless steel Stainless steel, Silver FKM/EPDM, PTFE t t 10A to
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -