SUP port EHX I/O Cylinder port 2, 4 (A, B) 1, 3 (P, R) Serial unit: EX240 25-pin 26-pin 20-pin Conforms to IP67 Conforms to IP67 C3 (for 3.2) C4 (for 4) C6 (for 6) M5 (M5 thread) C8 (for 8) N9 (5/16") N1 (1/8") N3 (5/32") N7 (1/4") C4 (for 4) C6 (for 6) C8 (for 8) C10 (for 10) N3 (5/32") N7 (1/4") N9 (5/16") N11 (3/8") C8 (for 8) C10 (for 10) C12 (for 12) Rc 1/2 N7 (1/4") N9 (5
VCS Series Lead wire length 20 30 40 Class 2 Class 3 Class 4 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Clip Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Note) Grommet type only Electrical entry Flat head screwdriver Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
V or less L3: Analog output: 1 to 5 V or 0 to 10 V can be selected.
L4 L1 L2 L3 L4 L n 12 260.5 250 229 16 L n 12 273 262.5 239.5 17 10 235.5 225 208 14 11 248 237.5 218.5 15 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5 218.5 15 11 260.5 250 229 16 13 285.5 275 250 18 14 285.5 275 260.5 12.5 15 298 287.5 271 13.5 16 310.5 300 281.5 14.5 L1 L2 L3 L4 L1 L2 L3 L4 402 Series 10-SZ3000 EX510 Gateway-type
Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
7 44.5 (Station 1) (Station n) 4 x M3 x 0.5 depth 6 (Bracket mounting screw) L Dimension n L n: Stations 1 35 27 20 396 388 13 32 51 70 89 108 127 146 165 184 203 222 241 260 279 298 317 336 355 374 2 54 46 3 73 65 4 92 84 5 111 103 6 130 122 7 149 141 8 168 160 9 187 179 10 206 198 11 225 217 12 244 236 13 263 255 14 282 274 15 301 293 16 320 312 17 339 331 18 358 350 19 377 369 L1 L2 L3
Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
Number of needle rotations Dimensions D3 Applicable tubing O.D. d D1 L3 A L4 M T H (Width across flats) L2 L1 Metric Size/Inch Size [mm] Model d T H D1 D3 L1 L2 L3 L41 A2 M Weight [g] Unlocked Locked Unlocked Locked AS121F-M3-02A-X790 2 11.9 5 AS121F-M3-23A-X790 3.2 7.2 17.2 21.7 5.8 15.8 20.3 16.9 13.3 AS121F-M3-04A-X790 4 8.2 AS121F-M3-06A-X790 6 10.4 18.6 23.1 16.5 6 AS121F-M3-01A-X790
Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.
Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
In-line Type Applicable tubing O.D. d Inch Size Metric Size Applicable tubing O.D. d Applicable tubing O.D. d Model Weight D1 D2 L1 L2 M1 L3 Max. Min. (g) Model Weight D1 D2 L1 L2 M1 L3 Max. Min.
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-M3 x 0.5 depth 6 (Bracket mounting screw) (Pitch) n-Rc 1/8 (A port) L Dimension n: Stations n L 1 37 27 2 56 46 3 75 65 4 94 84 5 113 103 6 132 122 7 151 141 8 170 160 9 189 179 10 208 198 11 227 217 12 246 236 13 265 255 14 284 274 15 303 293 16 322 312 17 341 331 18 360 350 19 379 369 20 398 388 L1 L2 L3
V100 SY (L5) Plug assembly 1 2 3 2-4.5 mounting hole (L4) SYJ VVQ100-12A(L3) 88 (8.5) L2 VK 48.7 L1 VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT (45) (35) 33 25 (5.5) 23.5 VP 12.3 VG R11 (Min. bending inner radius) Manual override 21.5 (29.3) VP 104 S070
N L1 L2 Port B min. port size L3 L4 L5 L6 D P Q1 Q2 MA MB FA FB KRM11-06-10-10 KRM11-06-10-6 80 10 6 6 10 40 47 23.3 13 19.5 33.5 23.5 33 13.5 19 22 8.5 10 106 6 89 10 120 55 73 53 55 KRM11-08-12-10 KRM11-08-12-6 8 12 25.7 15.5 22.5 37.5 26 36.5 20.5 24 10 11.5 14.7 86 74 KRM12 Weight (g) Applicable tube O.D.(mm) Thread Rc(PT) H (Hex.) Port B min. port size Part No.
SY SYJ (L5) Plug assembly (L4) VK 2-4.5Mounting hole 1 2 3 VVQ100-12A(L3) 88 (8.5) L2 VZ 48.7 L1 VT VT (45) (35) 33 25 (5.5) VP 23.5 12.3 VG R11 Manual override 21.5 (Min. bending inner radius) (29.3) VP 104 VQ VQZ Stations 1 2 3 4 5 n Dside Uside VZ 2-M5 X 0.8(E port) VS 2-M5 X 0.8(P port) 42.9 A A 20 (8.5) 1.5 5 n-M5 X 0.8 (A port) 5 (7.5) 15 P=10 38 Equation: L1=10n+32 L2=10n+43
30 80 50 5 192 40 100 60 5 232 45 Size D (g6) G H M N U UU L 30 8 6 13 10 8 53 63 7.8 50 15 11 27 20 15 89 109 14 63 17 13 29 22 17 105 127 16 80 20 15 38 25 20 130 155 19 100 25 19 44 30 25 156 186 24 Note) Dimension parts different from the standard conform to the general tolerance.
D-Y7P, D-Y7PV D-Y59B, D-Y69B D-Y59A, D-Y69A Internal circuits Lead wire length 0.5m 10 9 10 D-Y59A, D-Y69A Lead wire length 3m 53 50 53 Dimensions DC(+) Brown [Red] D-Y59A, D-Y7P, D-Y59B Main circuit of switch OUT Black [White] M2.5 x 4 Slotted set screw Indicator light 3.4 2.5 DC() Blue [Black] SMC 6.2 5 D-Y7P(V) 29 DC(+) Brown [Red] Main circuit of switch Most sensitive position 12.5 OUT