SMC Corporation of America
Elite Part Number Search
Search Results "AC20B-01-V-B"

Low Speed Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) MQ BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) RHC D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b,

Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.

25 M For positive pressure ZSE30 01 25 M For vacuum/low pressure Option 2 Piping specifications Nil None Bracket R 1/8 (With M5 female thread) 01 NPT 1/8 (With M5 female thread) A T1 Straight type 4 One-touch fitting 5/32" One-touch fiting C4H Output specifications Panel mount 25 65 26 28 NPN output PNP output 1 to 5 V output 4 to 20 mA output C6H 6 One-touch fitting B N7H 1/4" One-touch

Pin description Load is an analog input equipment such as a voltmeter, ammeter. 1 DC(+) PF2A7H-(-M) 68 69 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30 V 80 mA or less OUT1 Load Black H 0 V or Blue 50 msec 50 msec PF2A7H-(-M) 28 29 A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc1, NPT1, G1 36 M5 x

:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of

Model Option 10-/21-AW20(K)-B 10-/21-AW30(K)-B 10-/21-AW40(K)-B 10-/21-AW40(K)-06-B 10-/21-AW60(K)-B Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS AW62P-270AS Set nut Note 2) AR23P-260S AR33P-260S AR43P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Round type Note 3) Pressure gauge Note 4) Standard 10: G49-4-01, 21: G49-4-01-MS-X3 0.02 to 0.2 MPa setting Note 1) Assembly of a bracket

I"P.1/4, .. . , ASP530F-N03-11 S 3/S' ~ 25.9 1 51Jtr 11 / 16" 28.6 ~6~5 ~ 61 ;a.: ~:B-.9 :2D.S 220 tU6' /36,3 . 34:7 .26~ 21.7 . . ~ A efertlllCe dll'l'lerlSlons 1 01 NPT Ihmads aller installalion 3 Speed Controller 5 . ASP w"" P;lo' Ch.,k V,'v. efles Construction Parts list .QesCr;plian ' ''' fi1t~lal , . . .

Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00

)*7 Contact output signal 2 function RMT Contact output signal 2 operation A Contact output signal 2 selected alarm ---(AL.01)*7 Contact output signal 3 function ALM Contact output signal 3 operation B Contact output signal 3 selected alarm ---(AL.01)*7 *6: For more details of the default settings, refer to 5.20 Alarm Customizing Function. *7: For more details of the default settings, refer

/4 A OFF B+(A-B)/4 B -23No.PS-OMH0005CN-D CH1CH4 5R.D. 2 FSt FSt FSt (5R.D.)

DC1224 V( 10) DC1224 V(10 ) 6 DC(+) DC(-) DC1224 V( 10) DC1224 V(10 ) 7 DC(+) DC(-) / / / ( ) 8 9 -30No.PS-OMH0002CN-D No. () / () / 10 2030 20 "-M" 11 ( ) "-M" SI MPa 12 13 -31No.PS-OMH0002CN-D No. / / 14 () / () 15 () ( ) () () -32No.PS-OMH0002CN-D OUT1 OUT2 80 mA 07F.S. 3 0 1 digit 0 -27-67 -33No.PS-OMH0002CN-D ISE70() ISE75() ISE75H() 01 MPa 010 MPa 015 MPa -0.11

0.31 0.31 0.30 0.33 b 0.34 0.47 0.51 0.34 0.47 0.51 0.34 0.44 0.48 0.33 0.48 0.53 Cv 1.0 1.2 1.4 1.0 1.2 1.4 1.0 1.2 1.3 1.1 1.2 1.3 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 8 Rc VSA4120-01 VSA4120-02 VSA4120-03 VSA4220-01 VSA4220-02 VSA4220-03 VSA4320-01 VSA4320-02 VSA4320-03 VSA4420-01 VSA4420-02 VSA4420-03 2 position single VA 1 4 1 8 Rc 0.60 1 8 Rc 1 8 Rc SA 2 position double

65.5 P=25 A A A B A B A B A B A B 21 21 63 9 A A A A A A A 143 163 66 41.5 9 B B B B B SI unit Input block 10 n 1 2 3 4 5 6 7 Stations D-side 8 U-side Formulas L1 = 25n + 106 (Maximum 16 single wiring stations) L2: For one input block.

Power supply 24 VDC B B B Ground with a ground resistance of 100 or less without connecting the DC1 () lead (Blue) of the power supply cable to the power supply 0 V. Red A A +24 V Black Blue Charged object Charged object 0 V Reduced-wiring Fieldbus System F.G. (mm) Ground with a ground resistance of 100 or less. A B When using the autobalance sensor (body-mounting type) 10 20 20 40 3.

only) 3/8, 1/2 Port size (Nominal size B) 2.99 (3.09) 3.14 (3.24) 3.29 (3.39) Type M Weight (kg) (With auto-drain) 4.10 (4.20) 4.25 (4.35) 4.40 (4.50) Type V Note 1) For flow characteristics and pressure characteristics of regulator, refer to page 14-4-37.

Accessories Nil B None (standard) With bracket Note) When symbol B is indicated, a bracket assembly with a part number shown in the table below is included as an accessory.

L E T U B E OD Japan, Asia, Australia, UK N Canada, USA MM 23 3.2 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 B O D Y S I Z E 1 M5 2 1/8, 1/4 Standard 3 3/8 Standard 4 1/2 Standard T H R E A D P O R T S I Z E M5 ...M5 U01 ..1/8 U02 ..1/4 U03 ..3/8 U04 ..1/2 U32 ..10-32UNF 01 ... 1/8 02 ... 1/4 03 ... 3/8 04 ... 1/2 W I T H O N E-T O U C H F I T T I

Symbol Size Tubing connection 001 Same diameter tubing Symbol Model Oval type Round type H Male connector v v S Hexagon socket head male connector v v F Female connector v v L Male elbow v v LU Branch male elbow v V Universal male elbow v v W Extended male elbow v v T Male branch tee v v Y Male run tee v v D Male delta union v v U Branch Y v UD Double branch Y v M5 M5 x 0.8 01 R1/8, Rc1

to ports (A) and (B), both A and B strokes extend.

-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250 -69No.PF-OMN0011CN-C / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -70No.PF-OMN0011CN-C