Speed 600 mm/s (mm) Model A HP MM HT J LW LL L M HG HC HB HA H EB EA REAH15 REAH20 REAH25 42 8 19 M5 x 0.8 71.5 44 106 M5 x 0.8 17 45 33.5 33.5 46 21 26.5 97 50 8 23.5 M5 x 0.8 75.5 48.5 108 M5 x 0.8 16 53 41.5 42.5 54 22 26.5 102.5 58.5 10 28 M6 x 1.0 86 56 138 M6 x 1.0 25 61.5 46 46 63 24 29 125 Model N TW S ZZ Z XB W PP PB PA P NT NL REAH15 REAH20 REAH25 65 161 17.5 194 88.5 21 62 50

Calculate the load factor for each direction. x = Xc/Lx, y = Yc/Ly, z = Zc/Lz 5. Conrm the total of x, y and z is 1 or less. x + y + z 1 When 1 is exceeded, please consider a reduction of acceleration and work load, or a change of the work load center position and series. Acceleration [mm/s2]: a Work load [kg]: m Work load center position [mm]: Xc/Yc/Zc z y 1. Horizontal 3.

Z Y69BZ Note 2) Solid state auto switches marked with a " " are produced upon receipt of order.

(Example) For M4: L2 = 8 mm Applicable shaft types: X, Z Q1 = M C1 = C L2 = L2 = D1 = L1 + (3 x P) L1 = C1 Q2 = M Q2 = M Z axis X axis L1 = X = (mm) (mm) (mm) D1 5 to 7.9 5 to 14.9 5 to 16.9 8 to 19.9 8 to 24.9 L1 max Size 30 50 63 80 100 X 3 to 25 3.5 to 36 3.5 to 41 4 to 50 5 to 60 Q2 M3 M4, M5, M6, M8 M4, M5, M6, M8, M10 M4, M5, M6, M8, M10, M12 M5, M6, M8, M10, M12 Q1 M3 M4, M5, M6,

(Example) For M4: L2 = 8 mm Applicable shaft types: X, Z Q1 = M C1 = C L2 = L2 = D1 = L1 + (3 x P) L1 = C1 Q2 = M Q2 = M Z axis X axis L1 = X = (mm) (mm) (mm) D1 5 to 7.9 5 to 14.9 5 to 16.9 8 to 19.9 8 to 24.9 L1 max Size 30 50 63 80 100 X 3 to 25 3.5 to 36 3.5 to 41 4 to 50 5 to 60 Q2 M3 M4, M5, M6, M8 M4, M5, M6, M8, M10 M4, M5, M6, M8, M10, M12 M5, M6, M8, M10, M12 Q1 M3 M4, M5, M6,

When rod end female thread is used, use a thin wrench when tightening the piston rod. 712 Series CM2R-Z 10-/1121-/2220, 25, 32, 40 Direct Mount Cylinder RoHS How to Order Clean series 10 11 Relief type Vacuum suction type 10 C D M 2 R A 40 150 F Z M9BW 21 C D M 2 R A 40 150 F Z M9BW Mounting Number of auto switches Rod end thread A B Bottom Front Nil S n 2 pcs. 1 pc. n pcs.

at extension end) N-M5 X 0.8 thread 6 deep (Helisert) 6 4-M5 X 0.8 thread 7 deep 1 3.5 (With stroke adjuster at retraction end) 18 (With stroke adjuster at extension end) 26 35 62 48 F 20 5H9 deep 4 +0.030 0 2-M6 X 1 thread 10 deep N -1 X F 2 21 5H9 4 deep +0.030 0 10 M 0.5 36.5 40 Z ZZ (NN-1) X H G 24 10.5 24 10.5 H A B 10.5 10.5 5.1 9.5 26 1 5H9 4 deep +0.030 0 6 NN-M6 X 1 thread 12 deep

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

B With rod boot Z + 1/2 stroke A Rc BP lock-up port Unlocked when pressurized B Rc BP lock-up port Unlocked when pressurized 2-Rc P Width across flats KA Z + l + 1/2 stroke TDe8 EB EA D e Width across flats B1 l h + l ZZ + l + Stroke S + Stroke ZZ + Stroke 125 to 160 With rod boot Z + l + 1/2 stroke Z + 1/2 stroke A Rc BP lock-up port Unlocked when pressurized B Rc BP lock-up port 2-Rc

M5 x 0.8 x 7 14 53 4.3 5 M4 x 0.7 6 M5 x 0.8 32 18 21 17 25 84 REBR25 M6 x 1 x 8 15 70 5.6 6 M5 x 0.8 6.5 Rc 1/8 43 20 25.5 22.5 40 21.5 105 RB REBR32 M8 x 1.25 x 10 13 76 7 7 M6 x 1 8.5 Rc 1/8 54 26 33 28 50 27 116 J X Y Z Model REBR15 18 54.5 98 DREBR25 28 72 125 REBR32 35 79 148 -X 20Data 10-2-71 71 Series REBR Proper Auto Switch Mounting Position (Detection at Stroke End) A B C D 15

N 8 Z + Stroke Square nut for body mounting J TW (mm) Model A EA EB H HA HB HC HG HP HT J L LL LW M MM REBH15 REBH25 97 26.5 21 46 33.5 33.5 45 17 42 19 M5 x 0.8 106 44 71.5 M5 x 0.8 8 125 29 24 63 46 46 61.5 25 58.5 28 M6 x 1.0 138 56 86 M6 x 1.0 10 Model N NL NT P PA PB PP S TW W XB Z ZZ REBH15 REBH25 15 8 M5 x 0.8 50 62 21 161 65 88.5 194 17.5 16.5 20.5 18 9 Rc 1/8 65 75 27 209 75 103

( ) depth 4 +0.030 0 29.5 (Extension end adjuster) 10 Bottom view of MXQ12L-40 13228.5 J I 5.5 10 Vacuum suction port M5 x 0.8 Operating port 2 x M5 x 0.8 Max. 13 (Retraction end adjuster) 4H9 ( ) depth 4 +0.030 0 9 39 29 4H9 ( ) depth 4 +0.030 0 5 HA GA A B NN x M5 x 0.8 thread depth 10 9 8.5 9 4.2 4.2 A B 16 8 16 8 G (NN 1) x H H B-B A-A (mm) Model F 28 28 38 34 34 36 36 N 4 4 4 6 6 8

X 0.8 thread 8 deep 4H9 3.5 deep +0.030 0 8 M 0.5 28.5 32 Z ZZ (NN-1) x H G H 18.5 8.5 8.5 18.5 A B 4.2 8.5 9 9 20 1 5 4H9 3.5 deep +0.030 0 NN-M5 X 0.8 thread 10 deep 4H9 3.5 deep +0.030 0 A B HA GA Cross section AA Cross section BB (mm) Model F 35 35 35 50 35 55 65 GA 15 15 15 42 51 61 111 KA NA 2 2 2 2 2 4 4 Z 70 70 70 82 102 148 202 M 71 71 71 83 103 149 203 N 4 4 4 4 6 6 6 G 15 15 15

Calculate the load factor for each direction. x = Xc/Lx, y = Yc/Ly, z = Zc/Lz 5. Confirm the total of x, y and z is 1 or less. x + y + z 1 When 1 is exceeded, please consider a reduction of acceleration and work load, or a change of the work load center position and series. Acceleration [mm/s2]: a Work load [kg]: m Work load center position [mm]: Xc/Yc/Zc z y 1. Horizontal 3.

Position (Detection at stroke end) and Its Mounting Height CJ2Y-Z CM2Y-Z CG1Y-Z MBY-Z CA2Y-Z CS2Y CQSY CQ2Y-Z CJ2X-Z CM2X-Z CQSX CQ2X CUX (mm) Auto Switch Proper Mounting Position Auto switch model Band mounting D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-H7m D-H7C D-H7NF D-H7mW D-H7BA D-C7m D-C80 D-C73C D-C80C D-A9m D-A9mV A B A B A B A B Bore size 10 (5) 6 (5) 6 (1) 2 (1) 2 2.5 2.5 1.5

Z Y69BZ Note 2) Solid state auto switches marked with a " " are produced upon receipt of order.

Pad tYPe '--l (Avail diameters: Relerto List O) 5 M5 x 0.8 a o A 6 r , N / 6 x 1 a o a a M 8 x 1 a a , jo o q l d g > N44 x 0.7 o B5 M5 x 0.8 o o o B6 M 6 x 1 o a B8 lVlS x 1 .25 o a B0r '/e PT a a a o n g List O Pad Dia.

Pad tYPe '--l (Avail diameters: Relerto List O) 5 M5 x 0.8 a o A 6 r , N / 6 x 1 a o a a M 8 x 1 a a , jo o q l d g > N44 x 0.7 o B5 M5 x 0.8 o o o B6 M 6 x 1 o a B8 lVlS x 1 .25 o a B0r '/e PT a a a o n g List O Pad Dia.