SMC Corporation of America
Elite Part Number Search
Search Results "AL40-04-23-A"

Although the circuit at the output side of the switch is surgeprotected, damage may still occur if a voltage surge is applied repeatedly. When a load which generates a surge, such as from a relay or solenoid valve, is directly driven, use a switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications.

Silencer AN200-02 AN200-02 AN300-03 AN300-03 AN400-04 Caution on Pneumatic Circuit Design Air balance Unlike the current pneumatic cylinder that performs a simple reciprocal movement, the stroke reading cylinder with a brake also makes intermediate stops.

ZK2 CH A 2 04 L A KQ2P 06 Applicable stations 02 For 2 stations manifold 04 For 4 stations manifold 06 For 6 stations manifold 08 For 8 stations manifold 10 For 10 stations manifold d Models and Dimensions D Symbol Applicable size d A L D Weight [g] Note 06 6 18 35 8 1 White 08 8 20.5 39 10 2 White 07 1/4" 18 35 8.5 1 Orange 09 5/16" 20.5 39 10 2 Orange Connector type 1 D sub-connector (25

AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500

For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.

VPA300/500/700 Series VPA700 Series/Base Mounted/Dimensions 3/8, 1/2 2(A) port Standard/VPA744-103 04 A B 40 16 64 24 3/8, 1/2 3(R) port 1/8 12(PA) port 18 67 2 x 6.2 (For mounting) NO 2A NC 53 66 12 12 3R NC 1P (1/8) 12(PA) port 11.5 16 115.1 107.1 24 96.5 95.5 32.5 M5 x 0.8 (Breathing hole) 16 X 40 3/8, 1/2 1(P) port 80 03 04 A B For vacuum/VPA744V-13/8, 1/2 2(A) port 40 16 64 3/8, 1/2

For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.

2 A 2 A 24 VDC 0.63 A 1 A 1 A Temperature rise*5 25C 25C 25C 1 Leakage: The value at a differential pressure of 0.01 MPa or higher and an ambient temperature of 20C 2 This product has an IP67 enclosure, but if water enters the product, it may result in malfunction or breakage.

AS2002F-04-X12 Applicable tube O.D. Body size 100 200 205 300 400 Metric size Inch size M3, M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Grease-free (Sealant: Fluoro coated) + Restrictor (Without Check Valve) -X21 02 23 04 06 08 10 12 01 03 07 09 11 13 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

E E Effective thread K FA JC JC FB A NF C H S + Stroke B ZZ + Stroke (mm) H GA 80 FB 16 FA 10 EA 23 D 62 C 20 B 53 A E 0 Bore size (mm) Stroke range (mm) Effective thread length 50 70 35 32 250 to 1000 50-0.042 0 80 16 10 23 58 20 60 80 35 32 250 to 1000 63 55-0.074 0 90 20 10 23 61 25 75 95 40 37 250 to 1000 80 65-0.074 0 95 20 10 25 63 30 90 116 40 37 250 to 1000 100 80-0.074 J ZZ P 6.8

AS121FM-M5-23 AS121FM-M5-04 AS121FM-M5-06 AS221FM-01-23 AS221FM-01-04 AS221FM-01-06 AS221FM-01-08 AS221FM-02-04 AS221FM-02-06 AS221FM-02-08 AS221FM-02-10 3.2 4 6 3.2 4 6 8 4 6 8 10 22.1 22.1 22.9 27.5 27.5 27.5 32.4 34.4 34.4 36.4 43.2 8.4 9.3 11.6 9.3 9.3 11.6 15.2 10.4 12.8 15.2 18.5 17.3 17.3 18.1 20.4 20.4 20.4 25.3 25.2 25.2 27.2 33.9 12.7 12.3 7 28.8 25.1 30.1 9.6 33.8 M5 x 0.8 8 13.5

The float type auto drain used in the standard air dryer is replaced with a heavy-duty auto drain (ADH4000-04). * The IDF100F to 150F, 190D, 240D standard types are equipped with a heavy-duty auto drain.

Model A L D KQ2P-04 KQ2P-06 KQ2P-08 4 6 32 16 6 8 35 18 8 10 39 20.5 A A A A A B B 5 Series SZ3000 DIN rail dimension table/weight table D-sub connector (25 pins)/cable assembly VZ1000-11-11 VVZS3000-21A~ 3 Refer to the L dimension table Enter a number from the DIN rail dimension table below in the .

If there is a risk of contact, provide safety measures such as a cover or a system that uses sensors that will activate an emergency stop before contact is made. 2. Use a balance circuit in which lurching of the piston is taken into consideration.